background image

[email protected] (58) 341-05-06 | [email protected] (58) 341-38-80 | [email protected] (22) 100-42-99 

INTENDED USE 

INSTALLATION

The eco solar boost - 

Green Boost 3000

 

(DC 1210-350V)

 is designed to 

power heating devices such as boilers, heaters, electric heaters or heating 
mats directly from PV panels. 

The system requires: 4 to 9 typical PV panels (250W - 400W) connected in 
series, with a total voltage from 120V to 350V. 

Our inverter is equipped with internal maximum power protection of 3kW. 
However, the total power of the panels connected to the inverter should not 
be higher than 5kW.

Green Boost 3000

 

(DC 1210-350V)

 allows to connect two heating devices 

(e.g. two boilers). One will be heated first and the second one will be heated 
only,  if  the  thermostat  of  the  first  one  stops  receiving  energy  from  the 
inverter.This ensures that energy from the PV panels will not be lost when 
one of the units reaches a set temperature.

Green Boost 3000

 

(DC 1210-350V)

 is equipped with MPPT. Thanks to that, 

the inverter will automatically adjust to the power of boiler and maximizes 
the amount of energy drawn from PV panels.

To connect the PV panels to the inverter, use suitable PV installation cables 
with a cross section not less than 4mm. Using wires that are too thin will 
cause heating up and a voltage decreasing at the inverter input. In extreme 
cases it can cause a fire.

The inverter requires unobstructed air circulation for proper operation. Do 
not, under any circumstances, cover the ventilation holes as this may be a 
direct cause of overheating and damage of the device. 

To improve heat dissipation and for your own safety, we suggest to screw 
the inverter vertically to nonflammable surfaces (concrete, metal).

Summary of Contents for GREEN BOOST 3000

Page 1: ...LSKA Sp z o o ul Swiemirowska 3 81 877 Sopot www voltpolska pl sales voltpolska pl 58 341 05 06 przemek voltpolska pl 58 341 38 80 bartek voltpolska pl 22 100 42 99 GREEN BOOST 3000 ECO SOLAR BOOST FO...

Page 2: ...t signals od 25 55 Storage temperature od 20 45 Weight 2 7kg 345x215x120mm with MC4 TECHNICAL DATA GREEN BOOST 3000 Congratulations on choosing our high quality eco solar boost Green Boost 3000 DC 121...

Page 3: ...t of the rst one stops receiving energy from the inverter This ensures that energy from the PV panels will not be lost when one of the units reaches a set temperature Green Boost 3000 DC 1210 350V is...

Page 4: ...of a minute Any repairs should only be carried out by an authorised service centre Do not put the voltage inverter in a high humidity area near a re source ammable substances Do not also expose it to...

Page 5: ...will be con rmed by the LED indicator Optionally a second energy consumer can be connected to the inverter output marked 2 This can works only with a bi metal thermostats Electronic temperature contro...

Page 6: ...will be lit Otherwise it will blink OUTPUT PRIMARY It lights when socket 1 is working OUTPUT SECONDARY It lights when socket 2 is working PV VOLTAGE Actual PV input voltage PV CURRENT Actual PV input...

Page 7: ...s voltpolska pl 58 341 05 06 przemek voltpolska pl 58 341 38 80 bartek voltpolska pl 22 100 42 99 CONNECTING DIAGRAM 1 i 2 PRIMARY SECONDARY ACTIVE ONLY WHEN NO LOAD ON PRIMARY 2 1 PRIMARY SECONDARY M...

Page 8: ...ates that it is at the end of its useful life should not be disposed of with other household wastes To avoid harmful e ects on the environment and human health as a result of uncontrolled waste dispos...

Reviews: