37
Place the cover (12).
Tighten the cover screws (13).
Insert the central screw (14).
Tighten the nut with a wrench (15).
Place the clip with the nut and
assemble the screw (16). Tighten
the screw with an M4 Allen wrench
(17).
15.4 Tool Calibration
If a replacement motor or drive plate is required, the pruners need to be recalibrated.
Follow next steps to perform the calibration:
1)
Remove the upper and lower blades.
2)
Insert the battery.
3)
Hold down the trigger and keep it pressed. Press the POWER switch again.
4)
Maintain the trigger pressed for more than 10 s.
5)
Release the trigger when you hear the motor turning.
6)
The electric motor rotates during calibration. When the motor stops turning the calibration is
complete.
16.
Storage
•
Don’t disport the battery to hot or cold environment.
•
Remove the battery from the device if storage for a long time.
•
Storage the battery and charger into box to keep it away from hot temperature, dust and humidity.
Check switch is in OFF position before storage.
•
Battery should be storedin dry environment, see below:
Storage less than 1 month
-20°C ~ +60°C
Storage less than 6 month
-10°C ~ +35°C
Storage over 6 month
0°C ~ +30°C