35
4. Reinstall the cap and tighten sufficiently.
5. Connect the tank to the cabinet using the
sanitizer line.
6. Prepare detergent water by mixing several
drops of Dawn
®
dish soap with a gallon of
warm water (108°F / 42°C).
7. Rotate the 9-Tube Assembly coupler until it
unlocks and remove it from the Injector
Head syrup line opening.
8. Unlock the coupler body by rotating it from
the coupler base. Remove the coupler
body, syrup line manifold, and duckbill
check valve from the 9-Tube Assembly.
Submerge these parts in detergent water.
9. Place the end of the 9-Tube Assembly into
a container to catch the expelled syrup and
sanitizer solution during the rest of the
Clean-In-Place procedure.
10. Disconnect the syrup bag connectors from
the syrup bags.
11. Remove the Injector Assembly and adapter
from the freezer and disassemble them.
Submerge the Injector Head, Gear
Cartridge, Gear Box, nut, spout adapter,
and o-rings in detergent water with the 9-
Tube Assembly. Set aside the Drive Motor.
NOTE:
DO NOT SOAK THE DRIVE MOTOR
OR EXPOSE IT TO EXCESS WATER.
Summary of Contents for STOELTING Flavor Burst STL-40SS-JR