background image

1

2

3

4

5

6

8

10

9

12

11

16

15

14

24

25

7

13

19

21

22

17

18

20

23

ECOSYLER 08 APPLICATOR PARTS

26

Item No.

Description

1

Tank Lid

2

Neck Ring

3

Filter Basket

4

Mounting Bracket

5

Control Box Bracket

6

Control Box

7

Tank

8

Pump Housing Cover

9

Pump Housing

10

Pump

11

6mm Hose Tail

12

Quick Connector A

13

Quick Connector B

14

Nozzle

Item No.

Description

15

Quick Connector A

16

Quick Connector B

17

10mm Hose Tail

18

Reducing Bush

19

3 Way Valve

20

Tank Drain

21

Retaining Clip

22

Low Level Indicator

23

Braided Hose

24

Power Connecting Cable

25

Pump-Control Box Cable

26

Pump Tubing

-9-

00024_Ecosyler Guide_v2 0915

Summary of Contents for Ecosyl ECOSYLER 08

Page 1: ...ting mode 4 5 Counter 4 6 Alerts 4 6 1 Low Level 4 6 2 Pump 4 7 Control Box Menu 4 7 1 View the counter reading Counter tonnes or litres 4 7 2 Reset the counter ctr clr CTR 0 6 7 3 Application rate Do...

Page 2: ...et supplied 2 3 Nozzle The nozzle should be placed in the lower side of the chute approximately midway along its length eg fit into the centre of a convenient cleaning flap Drill a 14mm diameter hole...

Page 3: ...ches to Cleaning mode forward or twice 2 rapid clicks to Cleaning mode reverse Pressing the key takes you into the menu where you can reset the counter and change various applicator parameters see sec...

Page 4: ...both of which cause the Alert LED on the control box to flash and an audible warning which can be cancelled by pressing the key The display will return to normal but the red LED continues to flash un...

Page 5: ...NB Before returning to harvest mode you must confirm all 3 digits even if only one changed t h or l h rate of harvest or additive use Counter accesses the counter t or l total tonnes harvested or lit...

Page 6: ...e control box 8 Collect at least 500ml 4 minutes then stop the pump by pressing the key 9 View the counter reading in litres 10 Divide the amount of inoculant collected by the counter reading the coun...

Page 7: ...becoming constricted due to prolonged compression at the contact points see below Alternatively once a week remove the clear pump cover and red disc and manually turn the central hub to a new positio...

Page 8: ...for constrictions or breaks in the tubing and blockages including in the pump Control box power light on but nothing showing on LCD screen Try switching the power source off and on again ie switch ha...

Page 9: ...l Box 7 Tank 8 Pump Housing Cover 9 Pump Housing 10 Pump 11 6mm Hose Tail 12 Quick Connector A 13 Quick Connector B 14 Nozzle Item No Description 15 Quick Connector A 16 Quick Connector B 17 10mm Hose...