background image

1. SUPPLIED

1.  22 litre tank with 3-way valve
2.   electronic control box with 8 character LCD display
3.   positive displacement peristaltic pump (150 - 7500 ml/h)
4.   electronic low level indicator
5.   stainless steel nozzle with quick connector
6.   10 metres braided PVC tubing (int. Ø ¼ inch)
7.   7 metre electrical control box/pump connector cable
8.   1.5 metre power connector cable

2. INSTALLATION

2.1 Tank/Pump

Position where it will be easily accessible for filling, draining off excess inoculant and cleaning. For instance it could be 
attached to the platform railings or to the side of the harvester behind the driver’s cab.  

It should not be mounted inside 

any of the harvester compartments where elevated temperatures would be detrimental to the survival of the 
inoculant bacteria.

2.2 Control Box

Attach to a convenient point inside the harvester cab using the fixing bracket supplied. 

2.3 Nozzle

The nozzle should be placed in the lower side of the chute, approximately midway along its length, 
eg fit into the centre of a convenient cleaning flap. Drill a 14mm diameter hole in the centre of the 
flap and screw the nozzle in place, pointing up the chute once the flap is re-attached. 

 

3. ELECTRICAL CONNECTIONS

1. 

All connections are via quick connectors 

(to couple the electrical quick connector, line up the notch inside one end  

 

with the gap in the other end then screw the two parts together tightly using the two dimpled nuts, screwing them in  

 

opposite directions). 

2.  Connect the pump to the control box using the long connecting cable
3.  Connect the control box to the power source 

For a harvester with a table sensor -

 connect the control box directly to the power source according to the wiring 

colours shown below. 

For a harvester without a table sensor - 

either cut off the grey wire or attach it to the positive or negative (GND) 

terminal. 

-2-

       

   Power Source

Positive (+ve) BROWN
Negative (-ve or GND) BLACK
Table Sensor (+ve) GREY

Control 

Box

Pump

Summary of Contents for Ecosyl ECOSYLER 08

Page 1: ...ting mode 4 5 Counter 4 6 Alerts 4 6 1 Low Level 4 6 2 Pump 4 7 Control Box Menu 4 7 1 View the counter reading Counter tonnes or litres 4 7 2 Reset the counter ctr clr CTR 0 6 7 3 Application rate Do...

Page 2: ...et supplied 2 3 Nozzle The nozzle should be placed in the lower side of the chute approximately midway along its length eg fit into the centre of a convenient cleaning flap Drill a 14mm diameter hole...

Page 3: ...ches to Cleaning mode forward or twice 2 rapid clicks to Cleaning mode reverse Pressing the key takes you into the menu where you can reset the counter and change various applicator parameters see sec...

Page 4: ...both of which cause the Alert LED on the control box to flash and an audible warning which can be cancelled by pressing the key The display will return to normal but the red LED continues to flash un...

Page 5: ...NB Before returning to harvest mode you must confirm all 3 digits even if only one changed t h or l h rate of harvest or additive use Counter accesses the counter t or l total tonnes harvested or lit...

Page 6: ...e control box 8 Collect at least 500ml 4 minutes then stop the pump by pressing the key 9 View the counter reading in litres 10 Divide the amount of inoculant collected by the counter reading the coun...

Page 7: ...becoming constricted due to prolonged compression at the contact points see below Alternatively once a week remove the clear pump cover and red disc and manually turn the central hub to a new positio...

Page 8: ...for constrictions or breaks in the tubing and blockages including in the pump Control box power light on but nothing showing on LCD screen Try switching the power source off and on again ie switch ha...

Page 9: ...l Box 7 Tank 8 Pump Housing Cover 9 Pump Housing 10 Pump 11 6mm Hose Tail 12 Quick Connector A 13 Quick Connector B 14 Nozzle Item No Description 15 Quick Connector A 16 Quick Connector B 17 10mm Hose...

Reviews: