Fig. 4
Spare
Red/Black
White
White/Red
Blue
A.
Installation of the Vokera time switches (24 Hr and 7Day)
Remove the clock aperture blanking plate (1) fig.1 by
removing the securing screws and pulling the plate
out.
Remove the clock from it’s box.
Wire the clock as shown in fig. 4.
Insert the clock into the aperture from the back of the
control panel, and secure the clock to the front control
panel using the four screws provided. (See fig. 2)
Connect the other ends of the wires as detailed below.
(fig.3)
White/Red:
Connect to terminal marked L.
Blue: Connect to terminal marked N.
Red/Black:
Connect to terminal 5.
White: Connect to terminal marked 4, (remove link
wire connected between terminals 4 - 5.)
ROOM THERMOSTAT
Remove the loop between terminals 1 & 2 and
connect room thermostat as fig 5 or 5a.
FROST THERMOSTAT
Connect to terminals 2 & 3. If a neutral is required
use terminal marked N. (terminal 3 is a permanent
live)
NO EXTERNAL OR INTERNAL CONTROLS
The loops between terminals 1 & 2 and 4 & 5 remains
when no external or internal controls are used.
Instructions for
(A) Fitting Vokera 24 Hour Time Switch (Part No. 201)
and Vokera Digital 7 Day Time Switch(Part No. 202)
(B) Wiring to external Time Switches, Room Thermostats and Frost Thermostat.
(C) Wiring for 'S' & 'Y' Plan Installations.
1
SECTION 10 APPENDIX
Fig. 1
1
230v ~ Output for
Time Clock
Motor Supply.
Terminals 4 to 5 are
230v for control circuits
only.
Fig. 3
2
3 4 5
Fig. 2
Anticipator
Live
Load
N
Remove Link
Between 1 & 2
Fig. 5
Typical room
thermostat
1
3
2
4
5
6
Link 1 & 4
in r/stat
Fig. 5a
Vokera room
thermostat
Remove Link
Between 1 & 2