![VOKERA Maxin 24e Installation & Servicing Instructions Manual Download Page 38](http://html1.mh-extra.com/html/vokera/maxin-24e/maxin-24e_installation-and-servicing-instructions-manual_1044988038.webp)
37
MAXIN 24e & 28e
CHECK BOILER
STARTUP: TEST A
IS
240V AC PRESENT
BETWEEN TERMINAL
M2.4 & NEUTRAL
ON PCB
YES
NO
IS
240V AC PRESENT
BETWEEN TERMINAL
M2.2 & NEUTRAL
ON PCB
YES
NO
NO
CHECK WIRING AND
CONNECTIONS BETWEEN
TERMINAL BLOCK AND
CIRCUIT BOARD
REPLACE
CIRCUITBOARD
REPLACE FUSE
FUSE OK
CHECK FUSE
ON CIRCUIT
BOARD
RECHECK SUPPLY, FUSE &
CONNECTORS TO BOILER
TERMINALS
IS
240V AC
PRESENT
BETWEEN LIVE &
NEUTRAL ON
TERMINAL
BLOCK
IS
240Vac BETWEEN
TERMINALS M2.1 &
M2.5 ON
PCB
E
CHECK WIRING AND
CONNECTIONS BETWEEN
TERMINALS BLOCK AND
CONTROL BOARD OF TIMER
CIRCUIT AND ROOM
THERMOSTAT CIRCUIT
YES