![VOKERA AquaNova Installation & Servicing Instructions Manual Download Page 12](http://html1.mh-extra.com/html/vokera/aquanova/aquanova_installation-and-servicing-instructions-manual_1044985012.webp)
10
Fig. 12
Fig. 13
Fig.14
Convertor box
Condensate trap
4.6
CONNECTING THE GAS AND WATER
The appliance is supplied with an accessories
pack that contains sealing washers and service
valves. The service valves are of the compression
type. When connecting pipe work to the valves,
tighten the compression end first, then insert the
sealing washers before tightening the valve to the
appliance.
NOTE
It will be necessary to hold the valve with one
spanner whilst tightening with another.
4.6.1
GAS (see fig. 4)
The appliance is supplied with a 15mm service
valve, connect a 15mm pipe to the inlet of the
valve and tighten both nuts.
NOTE
It will be necessary to calculate the diameter of
the gas supply pipe to ensure the appliance has
an adequate supply of gas.
4.6.2
COLD INLET (see fig. 4)
The appliance is supplied with 15mm stopcock for
the cold water inlet connection, connect a 15mm
pipe to the inlet of the valve and tighten the nut.
4.6.3
HOT WATER OUTLET (see fig. 4)
The appliance is supplied with 15mm connector
for the hot water outlet connection, connect a
15mm pipe to the outlet of the connector and
tighten the nut.
4.7
ELECTRICAL CONNECTIONS
The electrical supply must be as specified in 3.7.
The appliance is supplied, pre-wired with a 0,9
metre length of flex, connect the wires as follows:
●
connect the Brown wire to the L (Live) terminal
of the plug or fused isolator;
●
connect the Blue wire to the N (Neutral) terminal
of the plug or fused isolator;
●
connect the Green/Yellow wire to the E (Earth)
terminal of the plug or isolator;
●
ensure the plug or fused isolator is fitted with a
3-amp fuse.
4.7.1
CASING REMOVAL
To gain internal access to the appliance you must
first remove the casing, proceed as outlined below:
●
locate and remove the 4 screws that secure the
controls fascia to the appliance casing (see fig. 14);
●
lift the casing upward to disengage it from the
top locating hooks and then remove;
●
gently lower the control fascia until it rests;
●
store the casing and screws safely until required.
Re-fit in the reverse order.
Fig.15
Screws
Screws
Outlet test
nipple
Inlet test
nipple
Protective