14
© 2022 United States Stove Company
•
Make sure the burn pot is free of pellets.
•
DO NOT open the viewing door.
•
DO NOT add pellets to the burn pot by hand.
NOTE: During the first few fires, your stove will emit an odor
as the high-temperature paint cures or becomes seasoned
to the metal. Maintaining smaller fires will minimize this.
Avoid placing items on the stovetop during this period
because the paint could be affected. Attempts to achieve
heat output rates that exceed heater design specifications
can result in permanent damage to the heater.
AUTOMATIC IGNITOR
1. Fill hopper and clean burn pot.
2.
Press the “On/Off” button. Make sure the green light
comes on.
3.
Adjust the feed rate to the desired setting by pressing
the “Heat Level Advance” button.
If the fire doesn’t start in 12 minutes, press “On/Off”, wait
a few minutes, clear the burn pot, and start the procedure
again.
OPTIMAL OPERATION
This pellet stove has been certified by the US EPA to
meet strict 2020 guidelines. To insure this unit produces
the optimal minimal emissions, it is critical to follow the
following guidelines. To achieve a “high burn”, your stove
should be set on setting 5 with the damper fully open.
To achieve a “medium burn”, your stove should be set
on setting 3 with the damper closed 50%. To achieve a
“low burn”, your stove should be set on setting 1 with the
damper fully closed. Setting 4 will give you a medium high
burn and setting 2 will give you a medium low burn. If the
door is opened while the stove is in operation it must be
closed within 30 seconds or the stove will shut down. If
the stove shuts down push the “On/Off” button to re-start
your stove. The stove will have to fully shut down and turn
off before you will be able to restart the stove
OPENING DOOR
CAUTION:
• DO NOT OPERATE YOUR STOVE WITH THE
VIEWING DOOR OPEN. THE AUGER WILL NOT
FEED PELLETS UNDER THESE CIRCUMSTANCES
AND A SAFETY CONCERN MAY ARISE FROM
SPARKS OR FUMES ENTERING THE ROOM.
• THE DOOR MUST BE CLOSED AND SEALED
DURING OPERATION.
If the door is opened while the stove is in operation it must
be closed within 30 seconds or the stove will shut down. If
the stove shuts down push the “On/Off” button to re-start
your stove. The stove will have to fully shut down and turn
off before you will be able to restart the stove.
ROOM AIR FAN
When starting your stove the Room Air Fan will not come
on until the stove’s heat exchanger warms up. This usually
takes about 10 minutes from start-up.
IF STOVE RUNS OUT OF PELLETS
The fire goes out and the auger motor and blowers will run
until the stove cools. This will take 30 minutes or longer
depending on the heat remaining in the appliance. After
the stove components stop running all lights on the display
will go out and the two digit display will begin flashing “E3”
OPERATION INSTRUCTIONS