Installation
Back wall / Arrière Mur
Side w
all / P
ar
oi La
tér
ale
Side w
all / P
ar
oi La
tér
ale
Back wall / Arrière Mur
Side w
all / P
ar
oi La
tér
ale
Side w
all / P
ar
oi La
tér
ale
Back w
all / A
rr
ièr
e M
ur
Ceiling / Plafond
Floor Protector / Protection de Plancher
C
B
A
E
E
D
D
F
G
K
H
L
J
M
M
FLOOR PROTECTOR
The stove must be placed on solid concrete, solid masonry, or when installed on a combustible floor, on a
Type 2 floor protector listed to standard UL 1618 with a minimum R value of 1.03 and a minimum thickness of
1/2” or equivalent. The floor protector is required to provide heat, live ember, and ash protection and must
be of a non-combustible, continuous solid surface to protect against infiltration of live embers and ash. For
UL Listed floor protectors, refer to manufacturers instructions for installation directions. Manufacturers of listed
floor protectors include Imperial Metal Products and Hy-C among others. To calculate R-Values for alternative
methods, see Alternate Floor Protector Calculation Methods in the back of this manual.
Dimension
Inch mm
H*
Front
9
229
J
Flue rear
2
51
K**
Left
8
203
L**
Right
8
203
M
Flue Side
2
51
• Canadian installations require 18” (457mm)
• Canadian installations require 8” (203mm)
SPECIAL MOBILE HOME REQUIREMENTS
WARNING! - Do not install in a sleeping room
CAUTION! - The structural integrity of the mobile home floor,
wall, and ceiling/roof must be maintained.
In addition to the previously detailed installation requirements,
mobile home installations must meet the following
requirements:
•
The heater must be permanently attached to the floor.
1. There are two holes in the pedestal base, use 3/8” bolts
through the floor.
2. To attach the leg model use two 3/8-16 UNC bolts
through the floor.
• The heater must be electrically grounded to the steel
chassis of the mobile home with 8 GA copper wire using
a serrated or star washer to penetrate paint or protective
coating to ensure grounding.
• When moving your mobile home, all exterior venting must
be removed while the mobile home is being relocated.
After relocation, all venting must be reinstalled and
securely fastened.
• Outside Air is mandatory for mobile home installation. See
your dealer for purchasing.
•
Check with your local building officials as other codes
may apply.
Mobile Home Attachment