116
11.1
Accelerometers
Vibration transducer, with built in amplifier
Internally shielded and case isolated.
Technical specifications for VMI192
Sensitivity (+/-10%)
100mV/g
Frequency response
(±3dB) 0.4–13000Hz
(±10%) 1.0-9000Hz
Dynamic Range
±80 g, peak
Sensing Structure
Shear Mode
Internal resonance
26000Hz
Settling time
<2 Seconds
Bias Voltage
10-14VDC
Electrical Case Isolation
>10
8
ohm
Temperature range
-50 to 121 °C
Maximum Shock Protection
5000 g, peak
Electromagnetic Sensitivity
CE-Certified
Sealing
Hermetic Welded
Weight (without magnet)
51 grams
Case Material
316L Stainless steel
Mounting
¼-28 Tapped Hole
Mounting stud
M6 Adapter stud
Mounting Torque
2.7-6.8 Nm
M6 pin
bolt
Cable connector
Measuring
direction
Extension tip
Magnet, force 200N
Note! Use of the Magnet will reduce the linear frequency response to 2000-4000Hz
depending on the surface structure of the measuring point.
Use of the Extension tip will reduce the linear frequency response to 1200-2000Hz
depending on the surface structure of the measuring point.
Only use the extension tip at otherwise inaccessible points.