Warning!
Incorrect setting of the emissivity factor
can lead to considerable errors of
measured temperature.
Direct the IR temperature transducer towards the surface you want to measure. Keep a distance of approximately
200-500 mm (8- 20 inches)
between the instrument and the object
. Reduce the distance between the object and the instrument in accordance with the surface size.
Note: when you get the temperature that differs most to the surroundings, then you probably have got the right direction.
The measurement surface size related to the distance 8:1
Emissivity:
Set the
coefficient for surface reflection factor
(Emissivity factor) using the table below or check via a contact probe.
Select the item with (UP) and (DOWN) arrow keys.
Sound screen
Listening to a machine sounds enables analysis of gears and low speed bearings (<300 rpm) in an alternative way and can improve analysis
speed and quality.
Viber X3™
makes it possible for the user to listen to the machine while at the same time seeing the vibrations in the
instrument display.
Note that you must choose the
Vibration Screen
while the sound is enabled the see the vibration signal.
When a headphone set is connected to the
Viber X3
™, the
Sound Screen
can be used to adjust the sound volume (depending on hardware
version there is also a volume control on the headphone cord). Before changing volume, the
SOUND
function must be
ON
. Sound output
status is enabled (ON) or disabled (OFF) in the
Sound Settings
menu.
Material
Emissivity
factor
Heat sink, black anodized
0.98
Paper
0.97
Black paint, matt
0.97
Ice, smooth
0.97
Wood
0.94
Glass
0.94
Rubber, hard
0.94
Transformer paint
0.94
Concrete
0.93
Brick, mortar, plaster
0.93
Porcelain
0.92
Steel, oxidized
0.79
Cooper, oxidized
0.76
Steel, heat treated surface
0.52
Copper
0.04
Aluminium, bright
0.04
Warning!
To protect your hearing,
y
ou should always remove the headphones from your
ears when you move the sensor or re-connect the cable.
Emissivity:
Set the coefficient for surface reflection factor (Emissivity factor) using the table
below or check via a contact probe.
The following temperature settings are possible:
To exit Settings menu, just press again the (MENU) key.
All settings will be
stored into the permanent FRAM memory.
To change
Emissivity factor,
in the
Function menu
go to
Settings
then go to
Temp
scroll down to
Emissivity
and use the arrow keys to change the value.
Temp
°C
Emissivity
0,98
Alarm
DISABLED
Warning
60,0 °C
Danger
80,0 °C
ACCEPT
Item
Values
Set the Auto-shutoff time
Backlight
ENABLED or DISABLED
Auto-shutoff
ENABLED or DISABLED
Setting
20 sec, 30 sec, 40 sec, 1 min,
2 min, 3 min
Set the Auto-shutoff time
Unit
°C or °F
Alarm
ENABLED or DISABLED
Warning
0,00 - X
Keep key pressed to auto-repeat
Danger
0,00 - X
Keep key pressed to auto-repeat
Language
If nothing else is specified at order English will be pre set
Emissivity
0,79 - 1,00
Should be set in accordance with the target surface
Material
Emissivity factor
Heat, sink, black anodized
0.98
Paper
0.97
Black paint, matt
0.97
Ice, smooth
0.97
Wood
0.94
Glass
0.94
Rubber, hard
0.94
Transformer paint
0.94
Concrete
0.93
Brick, mortar, plaster
0.93
Porselain
0.92
Steel, oxidized
0.79
Copper, oxidized
0.76
Steel, heat treated surface
0.52
Copper
0.04
Aluminium, bright
0.04
Don’t use
Summary of Contents for VIBER X3
Page 2: ......
Page 38: ...Vibra on Measurement Instruments 36...
Page 39: ...Vibra on Measurement Instruments 37...
Page 41: ...Vibra on Measurement Instruments 39...
Page 43: ...Vibra on Measurement Instruments 41...
Page 46: ...Vibra on Measurement Instruments 44 Click on next...
Page 48: ...Vibra on Measurement Instruments 46 Click on next...
Page 58: ...Vibra on Measurement Instruments 56...
Page 59: ......