2 Installation
If the start-up menu does not appear on the screen, please check that cables are
connected as described in the chapter "Terminal connection", and that your
terminal / PC / WS is set to 8 bits per character, 1 stop bit and no parity.
Start-up menu
After power-on, the start-up menu is written to the terminal as shown in the
figure below. This menu identifies product model, firmware version, baud rate,
terminal type (default or previously selected type), and what kind of piggyback
module is installed (if any).
V M E T R O V B T - 3 2 5 C VHE+ ANALYZER
TERMINAL PORT
:
19K2 81N
HOST PORT
:
9 6 0 0 01N
TERMINAL TYPE
:
DEC VT-100/VT-102
PIGGYBACK CONNECTED: VBAT-PB
START-UP OPTIONS:
T: SELECT NEV TERMINAL TYPE.
C: CLEAR NON-VOLATILE MEMORY.
SELECT AN OPTION OR TYPE <CR> TO CONTINUE:
FIRMWARE VERSION: 4 9 9 . 120
Figure 10. Start-up menu (as shown when VBAT-PB installed).
The start-up menu contains two menu options described below. Both are
activated with a single key as indicated.
Select Terminal type (T)
The user-interface of the VBT-325 is fully screen-oriented, taking advantage of
the graphical properties of terminals like VT100 etc. This requires that the user
specifies which terminal or terminal emulator he is using. By typing 'T', a list of
the supported terminal types is given.
Usable terminal types are:
1. D E C VT-100/VT-102
2. V M E T R O VT-100 EMULATOR / ANSI.SYS ON MDA SCREEN
VMETRO
V
B
T
-
3
2
5
User's Manual
2
1
Summary of Contents for VBAT-PB
Page 15: ...x i v 1 1 I 1 1 I I i i I I 1 I I 1 I 1 I I ...
Page 23: ...1VBT 325 Product overview 8 V B T 3 2 5 User s Manual V M E T R O ...
Page 125: ...8 Trace examples 110 V B T 3 2 5 User s Manual V M E T R O ...
Page 144: ...9 VBAT PB VME bus anomaly trigger ITP40 I GND VMETRO V B T 3 2 5 User s Manual 1 2 9 ...
Page 159: ...1 1Jumper settings 144 V B T 3 2 5 User s Manual V M E T R O ...
Page 181: ...16 Simulator for PC 166 V B T 3 2 5 User s Manual V M E T R O ...