15
Messages
Description of messages
Code
Viewing the status of the temperature probes. The message displayed in the
Check-Up indicates that the temperature reading on one or more probes is
equal to the minimum (0 °C) or maximum value (depends on the probe
considered). Check that the probes are not open (0 °C) or that they are short-
circuited (maximum value of the temperature scale).
probe
Open door. You must close the door!
door
Delay in stopping the equipment. The boiler was turned off when it was on.
Wait for this operation to complete.
OFF DEL
This message notifies you that the planned hours of operation (parameter T67)
are reached. Proceed to cleaning. To clear the warning see
Reset Clear
( rCLr )
CLr
Periodic cleaning running. Information message that the boiler is performing
periodic cleaning.
PCLr
Supply pellets
rFiL
Open hopper thermostat.
FLAM
Automatic periodic cleaning running
PCLr
State
State
Code
OFF
-
Verification
Check
Ignition-Preheating Phase
on 1
Ignition-Pre-Charge Phase
on 2
Ignition-Fixed Phase
on 3
Ignition-Variable Phase
on 4
Stabilization
on 5
Operation
-
Modulation
mod
Wait
STBY
Safety
SAF
Extinction
OFF
Block
Alt
Recover the ignition
rec