9.2.4. User menu
Menu
Descriptive
Combustion
management
Power
Allows you to modify the combustion power of the system in pellet mode. It can
be set to automatic or manual mode. In the first case, the system chooses the
combustion power. In the second case, the user selects the desired power. The
combustion mode (a = automatic combustion, m = manual combustion) and the
system's working power level are indicated on the left side of the display.
Auger calibration
Allows to edit the default value of speed or work time of the auger, increasing or
decreasing the quantity of pellets delivered. Values are in the range
–
7 ÷ + 7.
The default value is 0.
Calibration of the smoke extractor
Allows to edit the default value of combustion fan speed, increasing or decreasing
the combustion air volume. Values are in the range
–
7 ÷ + 7. The default value
is 0.
Heating
management
Boiler thermostat
Allows you to edit the temperature value set for the boiler. You can choose the
value between the defined minimum and maximum values.
Buffer Thermostat (Deposit)
Allows you to edit the value defined for the inertia tank or domestic hot water
tank. It will only be visible if the installation has the tank and if the installer has
configured it in one of the following options (P26 = 2, 3, 4).
Summer Winter
Option to be defined by the user depending on the station.
1.
Set winter to enable central heating.
2.
Select summer to disable central heating while maintaining domestic hot
water production.
Chrono
Menu to select the type of operating mode for the time schedule and the
operating time intervals.
Monitor
This Menu shows some data of the system of interest
Display
Description
T.Smoke
Smoke Temperature[°C]
Room T.
Ambient temperature detected by
the
board
[°C] (only visible if there is
a probe )
Buffer T.
Tank temperature [°C] ( Only visible
if
P26
=2, 3, 4 )
Pressure
Water pressure [ mbar ]
Air Flow
Air Flow [cm/s]
Fan
Combustion extractor speed [RPM]
( Only visible if
P25
=1, 2 )
Auger
Auger working time [s] (Only visible
if
P81
=0)