Scene
selection
Select the current operation scenario
1~10
10 scene setting formats
场景时间
Set the retention time of the current scene in auto mode, unit is 0.1 second
0
The current scene does not participate in automatic scene output
1-255
0..1 to 25.5 seconds
1. X axis
0-255
Set the data of each channel. The display content and sequence
correspond to the channel table of the fixture.
……
0-255
……
0-255
N. Function
0-255
If the effective reset data is edited in the reset channel in the scene, the fixture will be
reset, but after reset, the corresponding reset channel value will be automatically cleared to
prevent multiple consecutive resets.
View this page to get the current channel table order of the fixture. For detailed channel
data, please refer to the detailed channel description.
5.
Parameters Settings
Enter the page shown in Figure 6-5 to adjust the field parameters of the luminaire to
facilitate on-site installation of the luminaire, etc.
Advanced settings
X
axis
reverse
X axis reverse settings
Close
Do not reverse
Open
reverse
Y
axis
reverse
Set Y-axis rotation direction
Close
Do not reverse
Open
reverse
Optocoupler
correction
Set whether the fixture detects XY out of step and corrects it
Close
Uncorrected position after out of step
Open
Automatically correct position after out of step and record out of
step failure
X axis offset
Set the position of the zero point of the X axis of the fixture
4-150
Y axis offset
Set the position of the zero point of the Y axis of the fixture
4-48
Data
retention
Set the output status of the luminaire when there is no DMX signal
Close
No signal, the motor and light source return to the position and
state when reset is complete
Open
No signal, keep the last frame of DMX data output
Lighting
mode
Set the way to turn on the lamp for the first time after power on
lighting
Turn on the lamp when power on, reset the lamp after 30 seconds
Lighting
after reset
Reset the lamp 3 seconds after power on, turn on the lamp after
reset is completed
Manual
lighting
After resetting, manually turn on the lamp through the menu or
console