SPECIAL FEATURES

exclusively

Note

Application of RF keys

and

or

MHz provides enhanced security against

unauthorized management of the access control system. For this purpose the doorstation has a PIN-code, which
is recorded into RF keys memory during key binding, when keys are bound to a certain doorstation. If RF keys
memorized in the Control Unit are not bound to the doorstation, they will not be supported by the doorstation as
access keys

Furthermore  key binding allows making of duplicate RF keys

by the service company

To start the binding procedure a MASTER-key will be required, or a service personnel password.
A MASTER-key also allows change of a PIN-code and service personnel password, thus providing full management

of the access control system. MASTER-keys shall be kept safe, for instance, with head of the service company or
other entrusted person.

If the doorstation PIN-code has been changed, key binding shall be done again. Otherwise, the RF keys previously

memorized in the Control Unit will be no longer supported as access keys.

/

(13.56

)

.

,

.

VIZIT-RF3.x

VIZIT-RF4.x

.

PROGRAMMING

List of Settings

Memorizing MASTER-keys

all

Changing the doorstation PIN-code

Note

Programming the service personnel password

Binding RF keys to the doorstation

different

Order of programming

Memorizing MASTER-KEY No 1

6

MASTER-key No1

Note.

.

0000 0000

VIZIT-RF3.x

VIZIT-RF4.x

VIZIT-RF3.x

VIZIT-RF4.x.

-

0000 0000 (

),

-

.

-

PRG

GND

(

).

-

.

-

,

.

-

Preparation for operation involves certain settings, which are advised to be performed before installing the doorstation

on site (e.g., at the service company quarters)

If there is no need in enhanced security against unauthorized management of the access control system, the

programming procedure shall be skipped, and the doorstation PIN-code must remain as

(the default setting).

In this case the RF keys memorized in the Control Unit will be supported as access keys automatically, without the binding
procedure.

Memorizing of two MASTER-keys is available. MASTER-keys allow change of

settings of the doorstation. For this

purpose RF keys

or

may be used. MASTER-keys for different doorstations may be memorized

with use of the same keys

or

It is important to memorize two MASTER-keys, in case one of the keys is lost.

The PIN code is an 8-digit code of the doorstation, which is bound to RF keys. The PIN-code may be changed with

the MASTER-key. If the PIN-code is

default the procedure of key binding shall be skipped.

After the PIN-code has been changed, the RF keys bound to the old PIN-code are no longer supported as access

keys.

The password is required for RF key binding on site without the MASTER-key, or for change of the service personnel

password. The default setting is 0000 0000.

The key binding procedure involves recording of service data into RF key memory, the data corresponding to the

PIN-code of the doorstation. RF key memory allows binding to 7

PIN-codes. Later on during key binding, the data

on the last (the seventh) PIN-code is deleted to be replaced with the new data.
Key binding is done after RF keys have been memorized in the Control Unit. Order of key memorizing is described in the
operating instruction on Control Unit, and is similar to RF keys 125 kHz memorizing.

Connect the doorstation to the Control Unit  Make sure that the Control Unit’s power is off.
Connect

wire to

terminal of the Control Unit see the note on Figure

Switch the Control Unit on. The doorstation LED is showing
Approach an RF key close to the key reader. A short beep sounds, the LED is showing
then another short beep sounds, and the LED is showing

has been memorized.

Switch the Control Unit off, and disconnect PRG wire from GND terminal.

If after application of the RF key the LED keeps displaying            , it means that an error occurred during key

memorizing. Approach the RF key close to the reader once more.

·

·

·

·

.

1.

www.

- 43

201 -

/

vizit-group.com                                 BVD 3

F(FCPL) Operating Instruction  (revision

5 11)                                               5 8

Summary of Contents for BVD-343F

Page 1: ...e Abbreviations used in the model index RF keys reader and MHz colour camera pinhole lens IR LED illumination for camera Contents of multi apartment doorphone and video doorphone its features and orde...

Page 2: ...commended to protect the doorstation from rain snow and direct sun rays Order of installation with the mounting kit is given in the Mounting Kit operating instruction 2 3 Do not perform any connection...

Page 3: ...Terminals layout Holder for coaxial cable GND SP SP E MIC RX TX VG VO Terminals and circuit destination Video out for doorstation camera only for BVD 343FCPL Video ground only for BVD 343FCPL PRG RX...

Page 4: ...DL DL OP TM SP GND MIC E DSD 1 3 6 2 7 CONTROL UNIT BUD K K 302 20 80 RX SP TX 4 5 DL DL OP TM SP GND MIC E DSD 1 3 6 2 7 CONTROL UNIT BUD K K 302 20 80 V ELECTROMECHANICAL LOCK STRIKE 12 1 1N4007 8 8...

Page 5: ...ill be supported as access keys automatically without the binding procedure Memorizing of two MASTER keys is available MASTER keys allow change of settings of the doorstation For this purpose RF keys...

Page 6: ...key used Press button on the doorstation keypad A short beep sounds the LED is showing Enter eight digits of the current password using the keypad 0000 0000 is the default setting If the password is...

Page 7: ...ess buttons and simultaneously Release button first then button The LED is showing Start entering the password within 3 seconds The interval between entering digits of the password shall not exceed 3...

Page 8: ...back to the Control Unit s TX and RX terminals respectively and disconnect PRG wire from the GND terminal of the Control Unit is fully described in the control unit s operating instruction 1 2 3 4 5 6...

Reviews: