background image

www.vizaar.com

The device identification “INVIZ” stands
for a series of latest inspection cameras,
which are constructed strictly according
to the instructions of the users.

The video endoscope at hand,
”INVIZ BIG”, is currently the simplest and
at the same time most hard wearing
camera technology for the inspection and
documentation of weld seams and pipe
inner walls in the 30 mm – 300 mm
category. Expect high resolution, impres-
sive colours, highest light sensitivity, full
image, digital image and video memory
as well as a smart text generator option.

First models of the INVIZ BIG series and
previous are in the market since about 10
years and have been proved to be one of
the most ‘ruggedized’ inspection cameras
in the world. The percentage rate of
failure during the first two years of
operation is less than 5% - not reached
through any other RVI video - equipment
in today’s market place.

By continually and consistently not
including the electrical conductors of the
KEVLAR – reinforced main cable inside
one epoxy-glass fibre pushing pole, the
system keeps difficult flexibillity of tur-
ning multiple corners and bends without
breaking the main camera supply.
The immense amount of options and
custom made accessories will allow the
operator to reach any point of the
application:

::  Simple rotating and maneuvering of the

probe with attached  NEW side view optics.

::  Waterproofness up to 50 meter.
::  Longterm-tested durability of the entire

probe through high wall thickness of 
the probe.

::  Extremely light sensitive 40mm camera

head, interchangeable with 29mm
standard head.

::  Manoeuverability through many pipe 

bends. A widest range of pushing- and 
centering tools are supporting the 
operator to accomplish his task.

::  Easy focusing of the optics within a 

wide range of applications.

::  New several hours lasting

battery-operation option.

In order to obtain the economic advantages
of your endoscope even in the long run,
you ought to read and follow the following
advice, tips and warnings carefully. The
observance of these instructions serve
the purpose of your own safety as well as
the safety of those in the work field of the
endoscope as well as that of the
corresponding control device.

All tips, code of behaviour, suggestions
for measures to be undertaken, advice,
warnings and instructions are exclusively
valid for the operation of “INVIZ” BIG
videoscopes and not for devices by other
manufacturers.

For questions, which have not been
answered by this instruction manual,
your dealer and/or the manufacturer are
gladly available for advice. Kindly contact
us even if you have suggestions for the
improvement of this manual or the product.

We wish you success during your inspections!

Preface

:: 

Status / Revision: 10 / 2007

Summary of Contents for INVIZ BIG

Page 1: ......

Page 2: ...h any point of the application Simple rotating and maneuvering of the probe with attached NEW side view optics Waterproofness up to 50 meter Longterm tested durability of the entire probe through high...

Page 3: ...ve operation of the device beside the safety of the personnel and environment an extensive knowledge of the device the inspection technology the safety instructions as well as the industrial field of...

Page 4: ...or protection At the same time there is a danger that liquids might penetrate the probe and thereby impair the functioning permanently or might cause a life threatening electric shock to the operator...

Page 5: ...or increasing your own safety against electric shocks with risk of injury or loss of life the device must always be connec ted and operated via a residual current circuit breaker system or an isolatin...

Page 6: ...ily restricted power of vision When operating the device outside the permissible operating conditions or with destruction caused by usage which deviates from the instructions non compliance with the o...

Page 7: ...ever push the poles too strongly always inspect poles before starting the inspection Using the optional pushing poles cause additonal endangerment of the facility Always approve 100 push poles are con...

Page 8: ...tion battery operation 3 6 Option cable counter 3 7 Option 40mm head adapter 4 1 Image recorder 4 2 Integrated text generator 5 Getting Started 6 Care maintenance and repair 6 1 Cleaning of the system...

Page 9: ...port case check the container for possible transport damages DIM H 635 x W 510 x D 365 PE Weight empty 12 25 kg 1 Structure and start up www vizaar com 01 Open here Push center and lift to unlock Pull...

Page 10: ...m 02 1 Lift here 2 LCD Control Pendant 3 Watch alignment when packing 4 Umbilical cord for LCD 1 Mini keyboard under holding plate 2 Magic arm dismembered 3 Accessory pouch 4 Card Reader 5 Remote cont...

Page 11: ...cessory pouch or battery 1 Counter operation hrs 2 PS2 keyboard for option text generator 3 S Video video out only in combination with option data display modul 4 BNC composite video out 5 Connector u...

Page 12: ...in optional transport case 1 LCD operating pendant with digital image video recorder and actual high speed Flash Card Memory Card 2 Flash Card reader with USB connector 3 Mini PS2 keyboard US or D 4...

Page 13: ...an be disturbing equalizing current via the shielding of the cable The video image of the camera head can now be captured as so called Composite Signal video signal in common parlan ce via the lateral...

Page 14: ...st pixels of the camera during digitalization The manufacturer or your dealer will gladly advise you Avoid visual inspections under the influence of sunlight on the screen The connection of any kind o...

Page 15: ...ccess of your inspection work with the system PS2 connection socket in the control device To the extent that the optional text generator is integrated the mini keyboard included with the delivery or a...

Page 16: ...tate front housing until desired focus is set Hold back section while rotating front housing Do not remove front housing unnecessarily LED will shut off at nearest fokal point 1 5a Clockwise focus far...

Page 17: ...image resolution NTSC vertical 512 horizontal 492 Pixel PAL vertical 500 horizontal 582 Pixel 380 TV lines Min illumination requirement 1 5 lux Automatic white balance modus Ambient operation temperat...

Page 18: ...damaged connectors or clutches will cause tremendous trouble to the facility when camera head and other poles may left in a pipe after a 90 bend Always check the pole connectors before employing them...

Page 19: ...the application length and number of bends Rods and poles can be combined also poles of different flexibillity may be combined to reach the area of interest If the probe or camera head needs to be ro...

Page 20: ...eels reducing friction Pushing aids like epoxy fibre rods or poles are attached to the bigger trollies or directly to the probe when using smaller discs only Standard centering tools 3 Supplementary e...

Page 21: ...www vizaar com 13 3 Supplementary equipment Option centering trolly 3 2c 3 2d 3 2e 3 2f attach push pole insert camera head adjust close to nominal diameter 3 2...

Page 22: ...closing the camera head this is the most closest view possible Near view move lens away from camera housing FAR VIEW The end position of the side view optics to the distance ring is the farest focus...

Page 23: ...W The end position of the side view optics to the distance ring is the farest focus point within the illumination capabillity of the camera head Do not tighten the thread onto the distance ring Far vi...

Page 24: ...ch from recharching mode to operation mode you have to disconnect the charging equipment and connect the connection cable VE 100130 AE The battery must be disconnected from the camera before charging...

Page 25: ...ding on the environment the counter can be mounted with a clamping device or strong magnet close to the tube pipe entry like shown in the below pictures It is recommended to first install the cabel in...

Page 26: ...is kept easy to us button A toggles the counter OSD on off press button for seconds to reset counter to zero usually at the beginning of the tube button up B or down C will preset the counter to the...

Page 27: ...he 29mm head incl the behind loctated distance ring It is important no dirt can enter the open camera Be careful when starting winding the new optics onto the head do not damage the thread by rotating...

Page 28: ...or inadvertent removal of the card At the same time the imaging recorder ought to be protected from collisions or falls in order to prevent damage The imaging recorder ought to be regular ly cleaned w...

Page 29: ...n Note carefully Digital image data are not secure against illegal manipulation Make sure that you are able to reliably retrieve the obtained image data 10 years after the inspection and you are able...

Page 30: ...rd included in the delivery Now the inspection system can be switched on and can be activated with the main switch 4 of the LCD The system registers during the start phase with a blue screen and check...

Page 31: ...ssed Never continue to conduct the inspection with apparently defective imaging recorder or defective CF card There is risk of data loss Ensure that the AC voltage supply is secure A failure of the po...

Page 32: ...ymbol can be recognized in the lower left corner For the selection of a miniature picture move the selection indicator with In order to jump over several images keep a key pressed In the image preview...

Page 33: ...ll appear wherein the further procedure must be confirmed Press in order to highlight the desired folder Press in order to select the folder Alternatively you must select in order to abort the action...

Page 34: ...is displayed wherein the 6 alphabets can be determined Display direction In difficult working conditions the image can be turned upside down if need be at this point i e the operating pendant can be...

Page 35: ...ew folder Renaming the folder Select RENAME FOLDER in the main menu Proceed as described under the section Renaming a file OSD Under preparation Voltage saving mode Leave the setting on OFF as long as...

Page 36: ...s are blocked The operation of date and clock time is not coupled with the INVIZ imaging recorder and must be separately adjusted A few existing functions like photo coun ter positioning are no longer...

Page 37: ...Page up Page down Back Delete Alt Delete Shift Delete Ctrl Delete Tab Shift Tab ESC Enter Ctrl M Ctrl P Alt W nn F12 Help Menu F1 Ctrl F Ctrl H Alt M Help Menu F1 Ctrl S Ctrl W Help Menu F1 Ctrl B Ct...

Page 38: ...menu Use F1 key and go to page 4 with Page down Choose the desired command with and press An entry window appears wherein the respective value is entered in six digits Implausible entries like e g ho...

Page 39: ...h attribute For alternating between continuous and flashing display select the key combinati on Ctrl B The flashing mode remains active until it is switched off or the data write in is switched off Cu...

Page 40: ...atus and reactors this can lead to self obstruction similar to a lasso Do not lose your nerves in such a case there are often different methods of disengaging the probe without opening the plant or de...

Page 41: ...e for dangerous squeezes documentation of the destroyed probe sheathing braid removal of fraight wires Check of the LED s Safety check according to accident protection regulations and VDE Concluding r...

Page 42: ...b chapters of the different systems Operating conditions All individual operating conditions are listed in the individual sub chapters of the different systems General system data 96VAC 246VAC 30W con...

Page 43: ...Affix www vizaar com...

Reviews: