The identification plate is on the back of the appliance.

Once the end of use for the water 

dispenser has been reached, it must be 

dismantled and undergo environmen-

tally friendly disposal.

The dismantling and disposal is to 

be carried out exclusively by per-

sonnel of the manufacturers or by  

qualified persons.

The pictogram with the crossed out dustbin points to the requirement for 

separate disposal of electrical and electronic appliances (WEEE). Electri-

cal and electronic appliances can contain hazardous and environmentally 

hazardous materials. Do not dispose of this appliance as domestic waste. 

Hand it in at a collection point for electrical and electronic waste. The packing 

material is 100 % recyclable. The various parts must therefore be disposed of 

responsibly and in full compliance with local authority regulations. By doing so, 

you will help to conserve resources and protect the environment. For further 

details, please consult your dealer or your local authorities.

IDENTIFICATION PLATE

DISMANTLING AND DISPOSAL

WARNING!

Danger to life from improp-

er dismantling!

Errors in dismantling can lead to 

life-threatening situations or sub-

stantial property and environmental 

damage. This leads to risks, among 

other things, from electrical current, 

carbon dioxide or CO

2

 bottle pres-

sure.

• 

The dismantling is exclusively to 

be carried out by the manufacturer 

or qualified persons.

• 

Consult the manufacturer, even in 

the case of a change of location.

• 

Refrain from unauthorized disman-

tling and change of location.

TECHNICAL DATA

Dimensions:

Countertop (W x H x D) 

10.9 x 20.9 x 20.4 in

Floorstanding (W x H x D) 

10.9 x 56.3 x 20.4 in

Dispensing height 

13 in

Weight:

Countertop 

88 lb

Base cabinet 

15 lb

VIVREAU Top 85

Cooling Performance

22.5 gal/h

Flow rate

0.5 gal/min

Voltage

120 V

Current, max.

4.1 A

Power consumption, max.

510 W

Frequency

60 Hz

Fuse, min.

10 A

Protection Class

I

CO

2

 operation pressure

0.45 MPa / 65 psi

Inlet water pressure, max.

0.6 MPa / 87 psi

Inlet water pressure, min.

0.25 MPa / 36 psi (at 0.5 gal/min 

waterflow) 

System operating 

inlet water pressure

0.4 MPa / 58 psi

Inlet water temperature

41 - 77 °F

Temperature range

60 - 89 °F

Max. relative humidity

60%

Refrigerant: R290

1.9 oz (56 g) 

Noise emission

< 62 dB(A)

Height above the sea level

< 6500 ft

VIVREAU TOP Series

Specifications may vary due to further development and improvement of the 

products.

Summary of Contents for Top 85

Page 1: ...VIVREAU TOP SERIES EN Operating manual...

Page 2: ...hygiene is of the utmost importance and consists of three key elements 1 The inlet water filter includes pre fil ter activated carbon and membrane technologies The filter reliably retains tested bact...

Page 3: ...nt keep any kind of open fire sources well away and ventilate Important safety instructions Please read these safety instructions carefully before using the appliance Keep this manual in a convenient...

Page 4: ...up puddles of water using SAFETY INSTRUCTIONS the room thoroughly Turn off the appliance immediately Do not pull the plug out of the elec trical outlet as this can become a source of ignition Operate...

Page 5: ...ocal and regional require ments for the installation of devices connected to the public water supply SAFETY INSTRUCTIONS a cloth immediately Check the drip tray regularly and empty it if necessary Dan...

Page 6: ...al retailer Endangerment of the environ ment from improper handling of environmentally hazardous substances The improper handling of en vironmentally hazardous sub stances particularly improper dispos...

Page 7: ...and inquire about suitable measures to be taken The following environmentally hazardous substances are used R290 Refrigerants are ecolog ically friendly but a flammable product They could contain pois...

Page 8: ...ater dispenser may not be installed near direct or indirect heat sources Hoses and cables must not come into contact with heat sources The CO2 bottle must be placed as far as possible from any heat so...

Page 9: ...stop automatically when the preset quantity has been reached By pressing any water type button or by pressing stop button on display dispensing will stop imme diately 1 1 2 2 USING THE DEVICE The inst...

Page 10: ...n the units metrical C liter and em pirical F gal The unit will be saved automatically All settings can only be executed by the operator or the service technician To enter the menu swipe downwards wit...

Page 11: ...umption in gal l Filter capacity cold in gal l Last cleaning mode Detailed information about the device Status information Statistics on water consumption Statistics Status Info Menu Device type Devic...

Page 12: ...set two different portion sizes for each water type To enter portion setting mode 1 Enter the menu 2 Select Portion settings 3 Select portion setting size A or B The system will guide through the next...

Page 13: ...sinfectant al cohol spray suitable for food beverage contact use WARNING Danger to health from contamination Not following the hy giene guidelines can lead to contamination of the end product and coul...

Page 14: ...of improper handling the pressure on the CO2 bottle can lead to serious or even fatal injuries Before replacing the CO2 bottle Establish a pressureless state Also discharge residual pressure Always en...

Page 15: ...er a longer period of inactivity CAUTION After standstill times from 4 days up to 4 weeks flush the water dispenser with 2 5 gal of still water and 5 gal of sparkling water After a period of more than...

Page 16: ...see rear page Sparkling icons are dimmed CO2 bottle is empty Change the CO2 bottle see page 22 Standby Mode is active Touch the icons to wake up the system Others Problem Cause Remedy Water is warm I...

Page 17: ...nnect the water dispenser from the power supply 1 Disconnect the water dispenser from the power supply 2 Shut off the water supply and collect the leaked water Switch off the water dispenser 2 Shut of...

Page 18: ...antling Errors in dismantling can lead to life threatening situations or sub stantial property and environmental damage This leads to risks among other things from electrical current carbon dioxide or...

Page 19: ...1040546 01 2021 12 Vivreau USA 300 Roundhill Drive Unit 2 Rockaway NJ 07866 USA Telephone 1 877 999 1044 E Mail servicena vivreau com www vivreauwater com Local Distributor Dealer stamp...

Reviews: