8.17 Virtual input
(capability.nvi > 0)
Note:
Change virtual input (manual trigger) status.
Method:
GET
Syntax:
http://<servername>/cgi-bin/admin/setvi.cgi?vi0=<value>[&vi1=<value>][&vi2=<value>]
[&return=<return page>]
PARAMETER
VALUE
DESCRIPTION
vi<num>
state[(duration)nstate]
Where "state" is 0, 1. “0”
means inactive or
normal state while “1”
means active or
triggered state.
Where "nstate" is next
state after duration.
Ex: vi0=1
Setting virtual input 0 to trigger state
Ex: vi0=0(200)1
Setting virtual input 0 to normal state, waiting 200
milliseconds
, setting it to trigger state.
Note that when the virtual input is waiting for next
state, it cannot accept new requests.
return
<return page>
Redirect to the page
<return page>
after the
request is completely assigned. The
<return
page>
can be a full URL path or relative path
according the current path. If you omit this
parameter, it will redirect to an empty page.
Return Code
Description
200
The request is successfully executed.
400
The request cannot be assigned, ex. incorrect parameters.
Examples:
1. setvi.cgi?vi0=0(10000)1(15000)0(20000)1
No multiple duration.
2. setvi.cgi?vi3=0
VI index is out of range.
3. setvi.cgi?vi=1
No VI index is specified.