maxretentiontime <string>
6/6
To specify the expired time for automatic clean
up, and it only takes effect for video clip
generated by recording_i <0~1>.
Format is
“‘P[Y]Y[MM]M[DDD]DT[hh]H[mm]M[ss]S’
, similar with ISO8601 with symbols P
Ex. P7D, it means 7 days. P1DT10H, it means
1 days and 10 hours.
The parameter takes effect when
autocleanup_
maxretentiontime_recording_enabled is
enabled.
limitsize
<boolean>
6/6
0: Entire free space mechanism
1: Limit recording size mechanism
cyclic
<boolean>
6/6
0: Disable cyclic recording
1: Enable cyclic recording
notify
<boolean>
6/6
0: Disable recording notification
1: Enable recording notification
notifyserver
0~31
6/6
Indicate which notification server is
scheduled.
One bit represents one application server
(server_i0~i4).
bit0 (LSB) = server_i0.
bit1 = server_i1.
bit2 = server_i2.
bit3 = server_i3.
bit4 = server_i4.
For example, enable server_i0, server_i2, and
server_i4 as notification servers; the
notifyserver value is 21.