Water Temperature Set
WEATHER
TEMP.
SET
=
WEATHER
TEMPERATURE SET
WEATHER TEMP.SET function is used to
preset the desired water flow temperature
depending
on
the
outside
air
temperature.During the warmer weather the
heating is reduced.To save energy, the
weather temp.set can decrease the desired
water flow temperature when the outdoor
air temperature increased in heating mode.
Go to ''
MENU
'' >
''PRESET TEMPERATURE''
>
''WEATHER TEMP. SET''
. Press''
OK
''.
The following page will appear:
INFORMATION
WEATHER TEMP. SET have four kinds of
curves:
1. the curve of the high temperature
setting for heating,
2. the curve of the low temperature
setting for heating,
3. the curve of the high temperature
setting for cooling.
4. the curve of the low temperature
setting for cooling. It only have the
curve of the high temperature setting
for heating, if the high temperature is
set for heating.
It only have the curve of the low
temperature setting for heating, if the
low temperature is set for heating.
It only have the curve of the high
temperature setting for cooling, if the
high temperature is set for cooling
It only have the curve of the low
temperature setting for cooling, if the
low temperature is set for cooling.
See
''FOR SERVICEMAN
''>
''COOL
MODE SETTING
'' and >
''HEAT MODE
SETTING
'' in "
Installation and owner's
manual (M‐thermal split indoor unit)
".
The desired temperature (T1S) can’t be
adjusted, when the temperature curve
is set
ON
.
If you want to use heat mode in zone 1,
you select
''ZONE1 H‐MODE LOW TEMP''
.
If you want to use cool mode in zone 1, you
select
''ZONE1 C‐MODE LOW TEMP
''. If
you select ''
ON
'', the following page will
appear:
Use '
◄
'', ''
►
' 'to scroll .
Press ''
OK
'' to select.
Summary of Contents for HPS-22CH65AERI/O1 R32
Page 2: ......
Page 53: ...VIVAX HR 50 DODATAK B Dijagram ožičenja s električnim upravljanjem 4 10kW ...
Page 57: ...VIVAX HR ...
Page 58: ... HR VIVAX 1 ...
Page 89: ...VIVAX HR 32 STRUKTURA IZBORNIKA PREGLED ...
Page 90: ... HR VIVAX 33 ...
Page 145: ...VIVAX ENG 50 ANNEX B Electrically controlled wiring diagram 4 10kW ...
Page 149: ...VIVAX ENG ...
Page 150: ... ENG VIVAX 1 ...
Page 181: ...VIVAX ENG 32 MENU STRUCTURE OVERVIEW ...
Page 182: ... ENG VIVAX 33 ...
Page 187: ......
Page 205: ...3 4 3 4 3 4 ...
Page 208: ...ZZZ 9 9 FRP ...