Tightening Connection
• Align the center of the pipes.
• Sufficiently tighten the flare nut with fingers, and
then tighten it with a spanner and torque wrench
as shown in Fig.58 & 59
Outer
diam.
Tightening
torque(N.cm)
Additional tightening
torque (N.cm)
Φ
6.35
1500 (153kgf.cm)
1600 (163kgf.cm)
Φ
9.52
2500 (255kgf.cm)
2600 (265kgf.cm)
Φ
12.7
3500 (357kgf.cm)
3600 (367kgf.cm)
Caution
• Excessive torque can break nut
depending on installation conditions.
When select a 24K indoor unit
When select a 24K indoor unit, the manifold assembly
(not supplied) should be purchased and installed
together.
Installation method: when connecting the pipe,
connect the liquid pipe (thin pipe) and gas pipe (thick
pipe) of the manifold assembly to the high pressure
valve and low pressure valve of the outdoor unit as
identified with their respective matched numbers A&
B, as shown below.
Electrical work
Electric safety regulations for the initial Installation
1. If there is serious safety problem about the power supply, the technicians should refuse to install the air
conditioner and explain to the client until the problem is solved.
2. Power voltage should be in the range of 90%~110%of rated voltage.
3. The creepage protector and main power switch with a 1.5 times capacity of Max. Current of the unit should
be installed in power circuit.
4. Ensure the air conditioner is grounded well.
5. According to the attached Electrical Connection Diagram located on the panel of the outdoor unit to connect
the wire.
6. All wiring must comply with local and national electrical codes and be installed by
qualified and skilled electricians.
7. An individual branch circuit and single receptacle used only for this air conditioner must be available.
ELECTRICAL WORK
11
Summary of Contents for ACP-18COFM50AEEI
Page 1: ...Upute za uporabu User manual ACP 18COFM50AEEI RoHS 14 ...
Page 2: ...ENG User manual RoHS 14 ACP 18COFM50AEEI ...
Page 23: ...INSTALATION INSTRUCTIONS ...
Page 42: ...HR BiH Upute za uporabu ACP 18COFM50AEEI RoHS 14 ...
Page 63: ...UPUTE ZA UGRADNJU UREĐAJA ...
Page 83: ......
Page 87: ......
Page 93: ...3 4 ...
Page 100: ...3 4 3 4 3 4 ...
Page 109: ...www vivax com ...
Page 110: ...www vivax com ...