4. Indoor unit installation
1. Pass the piping through the hole in the wall.
2. Put the upper claw at the back of the indoor unit on the upper hook of the installation plate, move the indoor
unit from side to side to see that it is securely hooked (see Fig.12).
3. Piping can easily be made by lifting the indoor unit with a cushioning material between the indoor unit and
the wall. Get it out after finish piping.
4. Push the lower part of the indoor unit up on the wall, then move the indoor unit from side to side, up and
down to check if it is hooked securely.
Indoor units that can
be used in combination
Number of connected units
1-5units
Compressor
stop/start frequency
Stop time
3 min or more
Power source voltage
Voltage fluctuation
within ±10% of rated voltage
Voltage drop during start
within ±15% of rated voltage
Interval unbalance
within ±3% of rated voltage
1 drive2 1 drive3 1 drive4 1 drive5
Max. Length for all rooms
30m
45m
60m
75m
Max. Length for one indoor unit
20m
25m
30m
30m
Max. height different between
indoor and outdoor unit
OU higher than IU
10m
10m
10m
10m
OU lower than IU
15m
15m
15m
15m
Max. height different between indoor units
10m
10m
10m
10m
Fig.12
8
Summary of Contents for ACP-18COFM50AEEI
Page 1: ...Upute za uporabu User manual ACP 18COFM50AEEI RoHS 14 ...
Page 2: ...ENG User manual RoHS 14 ACP 18COFM50AEEI ...
Page 23: ...INSTALATION INSTRUCTIONS ...
Page 42: ...HR BiH Upute za uporabu ACP 18COFM50AEEI RoHS 14 ...
Page 63: ...UPUTE ZA UGRADNJU UREĐAJA ...
Page 83: ......
Page 87: ......
Page 93: ...3 4 ...
Page 100: ...3 4 3 4 3 4 ...
Page 109: ...www vivax com ...
Page 110: ...www vivax com ...