Page 11 of 62
™
2 vLoc3-5000 Receiver
2.5.5 The Classic Screen
The vLoc3-5000 Classic Screen has all the functions normally seen on a classic cable locator. The main functions are:
60.0
SIS-491kHz
24dB
68mA
0.39m
2
1
8
7
3
4
5
6
1.
Percentage signal strength (mirrors the bar graph setting)
2.
Gain setting
3.
Only visible with SiS frequencies, “+” indicates correct line, “-” indicates incorrect line
4.
Bar graph signal indicator (changes color depending on distortion level)
Green
- Low distortion
Blue
- Minor distortion, proceed with care
Red
- Excessive distortion, treat all data and measurements with caution
5.
Compass line direction indicator (when using an SiS frequency, arrow points forward on correct line, it will reverse on
incorrect line)
6.
Line position indicator
7.
Peak level indicator
8.
Frequency selection (flashing frequency indicates frequency selection is not valid for this screen. Choose another
frequency)
Radio
SD-EUR
8kHz
8KFF
33kHz
83kHz
200kHz
Tip
When in a locate screen, pressing and holding the “f”
key will bring up the frequency table.
Use the “+” and “-” keys to navigate quickly to the
desired frequency. Press the “i” key to select a