5 Loc3-10SiSTx Transmitter
5.2 Transmitter Batteries – Li-ion and Alkaline
The 10-watt transmitter uses 12 x D alkaline cell batteries. An optional Li-ion battery tray is available as an accessory.
On all transmitters the battery status is shown on the transmitter's LCD. The letters “LP” will appear when the battery status
reaches only one bar. At this battery level, the max output current and power are limited.
The LED on the charger will show a red light indicating that the charge cycle is in progress. When the batteries are fully charged,
the LED will change to green.
Follow the instructions detailed in the General Safety & Care Information section of this document. Dispose of batteries following
your company’s practice and environmental standards the prevailing laws or recognized best practice. Always dispose of
batteries responsibly.
WARNING
Use only Vivax-Metrotech recommended charger.
Do not
attempt to replace the rechargeable batteries or remove battery covers.
Return to Vivax-Metrotech or a Vivax-Metrotech approved service center for replacement.
5.2.1 Charging the Li-ion Battery Tray
The rechargeable battery tray can be charged while attached to the transmitter or on its own. The battery condition (status) is
displayed on the transmitter's display.
1. Connect the charger to the charging socket on the transmitter's side or directly into the battery tray's charging socket.
2. The LED on the charger will glow red while charging and turn green when fully charged.
Charging Socket
Charging Socket
FUSE
Plug the charger into the charging socket on the side of the transmitter or directly into the battery tray
Battery Charger
- is supplied with the optional Li-ion battery tray.
Optional 12-volt DC Power Lead
- this 30ft/90m lead can be used to power
the transmitter when connected to a target line at high output levels for extended
periods. It will not charge the transmitter battery.
WARNING
Only use a charger supplied by Vivax-Metrotech Corp. Using non-approved chargers may result in
damage to the equipment or overheating/explosion.
NOTE
The rechargeable tray cannot be charged from a 12V DC source.
Follow instructions detailed in the General Safety & Care Information section of this manual. Only use the battery charger
supplied as using an unapproved charger may damage the battery pack and may cause overheating.