12 Alarm Messages
12. Alarm Messages
The abbreviated alarm message listed in Table 12-1 appears on the hand-held display
screen, computer terminal screen, or phone line voice prompt when an alarm condition
occurs.
Screen message
Description
60Hz too High
The 50/60Hz power noise voltage on the line
exceeds 50 V.
ELF Current too High
The ELF signal current is too high.
ELF Current too Low
The ELF signal current is too low.
ELF Resistance to High
The resistance of the ELF signal is too high.
ELF Resistance too Low
The resistance of the ELF signal is too low.
Fan Failed
The Fan Module failed.
LS Current too Low
The locate signal current is too low.
LS Resistance too High
The resistance of the locate signal is too high.
LS Resistance too Low
The resistance of the locate signal is too low.
PA Current Overload
The current Output of the Power Amplifier is
overloaded.
Temperature too High
The transmitter’s internal temperature is too high.
Table 12-1 Alarm Messages