E61
Motor exchanged
Connection to motor has been broken or a new motor has been connected. Reinitialise table
(RESET)
E62
Overcurrent
Complete overcurrent of control system due to overload
E63
External sensor or cable
not connected
External anti-squeeze bar or other accessory module not connected, if necessary check
plug connector
E64
Authentication error
Reinitialise table (RESET)
E65
Overcurrent or short circuit
If an error occurs during movement. Collision? Excessive load?
E67
Overvoltage
Unplug power adapter! Contact your Vitra retail partner.
E70
Change to the drive
configuration
Unplug power adapter from mains and wait at least 5 seconds, then reinitialise the table
(RESET)
E71
Sensor – configuration
changed
An (optional) attached sensor has been removed or the connection has been lost.
Observe the special instructions for the sensor!
E81
Internal error
Memory or initialisation error, reinitialise the table (RESET)
E93
Connection error in cascaded
group.
Error is displayed for 15
seconds. After this, the control
system changes over to the
reset mode.
Check connection and reinitialise (RESET) the table
An error cannot be resolved as described: pull out the power adapter plug, wait a few minutes and try to reinitialise the table (RESET).
If the error then reoccurs, disconnect the table from the mains power and contact your Vitra retail partner.