Page 7
11. Trouble shooting
Malfunction
Possible cause
Remedial action
Power indicator (red LED) (1)
remains inactive
•
Power cord (8) not plugged in
•
Power cord (8) defective
•
Device defective
•
Plug in PERFECT FILTER
•
Please contact service
•
Please contact service
PERFECT FILTER is very noisy during
operation
•
Star handles (5) are loose
•
Rotor defective
•
Rotor scratches on the fryer
•
Tighten star handles (5)
•
Please contact service
•
Change the position of
PERFECT FILTER in the deep
fryer
Power indicator (red LED) (1)
flashes
•
Overtemperature
•
Let PERFECT FILTER cool down
•
Place PERFECT FILTER in a cool
place
PERFECT FILTER doesn’t start
•
Control unit (6) defective
•
Please contact service
Line fuse / Ground fault circuit fuse
(GFCI) blow-out
•
Power cord (8) or other electri-
cal components defective
•
Rotor defective / blocked
•
Circuit overloaded
•
Please contact service
•
Please contact service
•
Change socket/circuit
Low filtration performance
•
Particle filter is full
•
Pump-filter unit (9)
clogged
•
Motor defective
•
Change particle filter
•
Empty pump-filter unit (9)
•
Boil out to remove heavy
contamination
•
Insert filter as described
•
Please contact service
Oil splashed sideways and / or at
the back of the pump-filter unit (9)
•
Particle filter full
•
Too much space between filter
cover and pump-filter unit (9)
•
Filter paper not inserted over-
lapping
•
Change particle filter
•
Please contact service
•
Insert particle filter as
described
Power and filter indicator (1 & 2)
flash 10 sec. after plugging PERFECT
FILTER in
•
Start / Stop button (3)
defective
•
Control unit (6) wet inside
•
Please contact service
•
Please let it dry
If you find any faults not listed here, please contact the VITO AG (manufacturer) customer service or your dealer!
Contact details can be found in chapter 2. Legal information.
Summary of Contents for PERFECT FILTER
Page 1: ...PERFECT FILTER User Manual ...
Page 11: ......