background image

Page 9

13. Declaration of conformity

Issued by 

VITO AG (manufacturer) | Eltastraße 6, 78532 Tuttlingen (Germany) | Phone : +1 (802) 658-6600 |

 

Fax : +1 (802) 864-0183

For the product

 PERFECT FILTER

:

 EU Patent Nr. 1326692  / U.S. Patent Nr. US7.052.605.B2

The professional oil and fat filtration equipment is manufactured and tested according the following standards:

 

For the purposed of the EU directives :

- 2006/42/EG  

Machinery Directive

- 2014/30/EU 

 Electromagnetic Compatibility

- 2014/35/EU  

Low Voltage Directive

- 2011/65/EU

  RoHS - Directive (Restriction of certain Hazardous Substances)

- 2003/10/EC  

Minimum requirements to protect the safety and health of workers

-

 

2012/19/EU 

 WEEE Directive

- EN 61000-6-1: 2019 

Immunity

- EN 61000-6-2: 2019

 Immunity

- EN 61000-6-3: 2011-09

 Emission

- EN 61000-6-4: 2020-09

 Emission

- DIN 18876: 2018-06

: Commercial kitchen equipment - Portable non-integrated oil / fat filtration equipment - Requirements and testing

with German, European and International (Non- European) standards

German standard DIN EN

European standard EN

International standard IEC (IEC/CISPR)

DIN EN 61000-6-1:2019-11

based on

EN 61000-6-1:2019

based on

IEC 61000-6-1:2016

DIN EN 61000-6-2:2019-11

based on

EN 61000-6-2:2019

based on

IEC 61000-6-2:2016

DIN EN 61000-6-3:2011-09

based on

EN 61000-6-3:2011-09

based on

IEC 61000-6-3:2006 + A1:2010

DIN EN 61000-6-4:2020-09

based on

EN 61000-6-4:2019

based on

IEC 61000-6-4:2018

DIN EN 61000-3-2:2019-12

based on

EN 61000-3-2:2019

based on

IEC 61000-3-2:2018

DIN EN 61000-3-3:2020-07

based on

EN 61000-3-3:2013 + A1:2019

based on

IEC 61000-3-3:2013-05

DIN EN 60335-1:2020-08

based on

EN 60335-1:2014-11

based on

IEC 60335-1:2010, modified

DIN EN 12100:2011-03

based on

EN 12100:2011-03

based on

ISO 12100:2011-03

DIN EN 60204-1:2019-06

based on

EN 60204-1:2019-06

based on

IEC 60204-1:2016, modified

DIN EN 55014-1:2018-08

based on

EN 55014-1:2018-08

based on

CISPR 14-1:2016 + COR1:2016

DIN EN 55014-2:2016-01

based on

EN 55014-2:2016-01

based on

CISPR 14-2:2015

-

-

VO (EG) Nr. 2023/2006

-

IEC 60884-2-1

-

VO (EG) Nr. 1935/2004

-

-

2002/72/EG

  DIN EN 10088-1:2014-12

-

-

-

-

  DIN 18876 A1:2018-06

-

-

-

-

  DIN 18876 A2:2018-06

-

-

-

-

  DIN 18876 A3:2018-06

-

-

-

-

  DIN EN 50396:2006-07

-

-

-

-

  DIN EN 61003-2:2017-06

-

-

-

-

  DIN EN 10095:2018-12

-

-

-

-

  DIN EN 10269:2014-02

-

-

-

-

  DIN EN 10302:2008-06

-

-

-

  89/109/EWG

-

-

-

-

  EGV 1935/2004

-

-

-

-

  80/590/EWG 

-

-

-

-

  DIN EN 82079-1:2013-06 

-

-

-

-

  ProdSG

based on

2001/95/EG

-

-

  LFGB

-

-

-

-

  DGUV-rule 110-002

-

-

Tuttlingen, 2022

Andreas Schmidt

CEO

VITO AG

Summary of Contents for PERFECT FILTER

Page 1: ...PERFECT FILTER User Manual ...

Page 2: ...Adjusting the filtration time 4 7 Filtration process 5 7 1 Preparing for filtration 5 7 2 Starting the filtration process 5 7 3 Stopping filtration prematurely 5 8 Storage cooling time 5 9 Changing the filter paper 5 10 Cleaning 6 10 1 Notes 6 10 2 Preparing for cleaning 6 10 3 Manual Cleaning 6 10 4 Cleaning with the dishwasher 6 10 5 Boil out 6 11 Trouble shooting 7 12 Waste disposal 8 12 1 Pack...

Page 3: ...ominal voltage 100 120V 10 50 60 Hz Nominal power consumption approx 2 2A at 115V Max power 300 W Noise level 85db User control Start Stop button 3 Operating temperature control unit 6 max 167 F 75 C pump filter unit 9 max 392 F 200 C recommended frying temperature max 347 F 175 C Storage temperature 50 F 86 F 10 C 30 C Weight 17 lbs 7 7 kg with drip pan 14 lbs 6 3 kg without drip pan Acoustic sig...

Page 4: ...icient support on the fryer 4 Safety instructions 4 1 Explanation of symbols Incorrect operation of the PERFECT FILTER can lead to danger and injury The following should be observed Possible dangers are marked with these symbols Warning Risk of injury if not observed Risk of electric shock due to incorrect handling or opening of the housing Risk of slipping Contamination on the floor possible Caut...

Page 5: ... 2 Checking the factory settings 1 Press and hold the Start Stop button 3 2 Plug in the power cord 8 Meanwhile hold the Start Stop button 3 3 Hold the Start Stop button 3 for 5 seconds 4 Release the Start Stop button 3 The filter indicator 2 lights up briefly 5 The programmed filtration cycle time is indicated by the flashing of the LEDs 6 The power indicator 1 shows 1 minute per flash 7 The filte...

Page 6: ...ping filtration prematurely 1 Press the Start Stop button 3 The filter indicator 2 shuts off 2 Lift PERFECT FILTER and let residual oil flow into the fryer 3 Store PERFECT FILTER in the drip pan 4 see chapter 8 Storage cooling time 8 Storage cooling time Place PERFECT FILTER in the drip pan 4 after use or for transport Permissible storage temperature 50 F 86 F 10 C 30 C Cooling phases Up to 2 5 ho...

Page 7: ...ual cleaning or cleaning with the dishwasher 10 3 Manual Cleaning 1 Clean the control unit 6 with a damp cloth DO NOT use running water This will damage the control unit 2 Wash the pump filter unit 9 and the drip tray 4 3 Dry PERFECT FILTER 10 4 Cleaning with the dishwasher 1 Clean the control unit 6 only with a damp cloth NEVER put the control unit 6 in the dishwasher This will damage the unit 2 ...

Page 8: ...ective Rotor defective blocked Circuit overloaded Please contact service Please contact service Change socket circuit Low filtration performance Particle filter is full Pump filter unit 9 clogged Motor defective Change particle filter Empty pump filter unit 9 Boil out to remove heavy contamination Insert filter as described Please contact service Oil splashed sideways and or at the back of the pum...

Page 9: ... dealer or the VITO AG manufacturer customer support 12 4 WEEE Waste Electrical and Electronic Equipment Directive Do not throw power devices in the household waste According to the European Directive 2002 96 EG on Waste electrical and electronic equipment and its implementation in national law not usable power tools are collected separately and recycled in an environmentally friendly manner Manuf...

Page 10: ...0 6 1 2019 based on IEC 61000 6 1 2016 DIN EN 61000 6 2 2019 11 based on EN 61000 6 2 2019 based on IEC 61000 6 2 2016 DIN EN 61000 6 3 2011 09 based on EN 61000 6 3 2011 09 based on IEC 61000 6 3 2006 A1 2010 DIN EN 61000 6 4 2020 09 based on EN 61000 6 4 2019 based on IEC 61000 6 4 2018 DIN EN 61000 3 2 2019 12 based on EN 61000 3 2 2019 based on IEC 61000 3 2 2018 DIN EN 61000 3 3 2020 07 based...

Page 11: ......

Page 12: ...Manufacturer VITO AG Eltastr 6 78532 Tuttlingen P 49 0 7461 1508050 F 49 0 7461 1508051 info vitofilter com www vitofilter com VITO is a registered trademark of VITO AG Germany ...

Reviews: