background image

 

 

 

29 

2.2

 

Product Specification

 

C MO S   S e n s o r  2 million pixels CMOS sensor 
L

e

n

Object lens 4X/10X/20X 

Magnification 

Object  lens  4X:  284x~425x;10  Object  lens  : 
721x~1041x;  20X  Object  Lens: 

1548x~2042x

  on  24” 

monitor 

Auxiliary  source  GN08 
DC            Port  Adaptor DC Input 
HDMI        Port  Mini HDMI Output 1080P(1920*1080 Pixel) image 
USB  3.0      Port  Type C output YUV/MJPE format; Max res. 1080P 
Focus  control  IR remote control 

Power  Supplier 

Adaptor   
(Output

DC 5.0V/2.0A Input

AC 100-240V 50/60Hz) 

P o

w

e

C o n s u m p t i o n   
(

A

/

C

)   

1A(Max)   

S

i

z

e    68(L)×66(W)×255(T) mm 

W e i g h t  Host weight around452 grams 
O p e r a t i o n 
e n v i r o n m e n t 

Temperature -5

  ~ 35

; Humidity-lower than 85% 

(No Condensation) 

F o r   a n y   c h a n g e s ,   p l e a s e   v i s i t   h t t p : / / w w w . v i t i n y. c o m 

*USB  3.0  transmission  speed  might  be  downgrade  depends  on  the 
device/host condition 

Summary of Contents for UM20-GN08

Page 1: ...Version 1 0A UM20 GN08 User s Guide DiGi Microscope...

Page 2: ......

Page 3: ...emble microscope with stand 2 1 3 IR Remote controller 4 1 4 Microscope menu functions 9 1 5 Microscope introduction 23 1 6 Microscope Focus 26 1 7 Microscope accessory 27 2 Printed Notice 28 2 1 Main...

Page 4: ...Guide 1 Power adaptor 1 Calibrator 1 S112 Stand Hex key included 1 Object Lens 4x A 1 Stand assemble guide 1 Object Lens 10x A 1 GN08 Hex key included 1 Object Lens 20x A 1 Light Adaptor 1 Software do...

Page 5: ...the HDMI cable b and adaptor c to HDMI monitor and power See below 1 2 3 Power On Off Press Power to turn on microscope Choose HDMI mode or Auto on HDMI monitor to output image Long press means press...

Page 6: ...1 Power Turn on off 2 HDMI When in HDMI mode the HDMI cable must connect with the screen and microscope 3 PC CAM When in PC CAM mode the USB cable must connect to a PC and microscope Please disable so...

Page 7: ...Motor Reset Recalibrates entire operation Returns to the lens position If a loss of electricity occurred during operation please reset the operation 7 Manual focus 7 1 Zoom in Zooms in speed increases...

Page 8: ...lose menu for setting Refer to Section 1 4 11 Up Choose the previous item if Crosshair is ON select other color 12 Down Choose the next item if Crosshair is ON select other color 13 Left Choose the ne...

Page 9: ...ion 16 1 2 SZ Step Zoom Ex SZ 500 Same format as OZ 16 1 3 AFS Single Autofocus Ex AFS A500 A means search focus in current area 500 means sensor position AFS W500 W means search focus in whole area 1...

Page 10: ...eans freeze image FRZ OFF means unfreeze image 16 1 10 WB White Balance Calibration Ex WB SET means calibrate white balance 16 1 11 NONE No Function 17 Auto White Balance Calibration To calibrate the...

Page 11: ...1 4 Microscope menu functions Press button to enter MENU press Up and Down to choose item Left and Right to turn on off or adjust parameter Enter means more functions press Menu to enter next function...

Page 12: ...10 1 4 1 EXPOSURE To set exposure time see below 1 Shutter Digitally control amount of light the amount is smaller the image is darker and the frame rate is also slower...

Page 13: ...ghtness 5 D WDR Digitally adjusting exposure in areas of the frame to maintain optimum detail in both the shadows and highlights of the image 5 1 LEVEL Adjust image exposure level from too dark or too...

Page 14: ...Return to Factory setting 6 4 RETURN Return to Last page or Save End Menu 7 RETURN Return to Last page or Save End Menu 1 4 2 BACKLIGHT Press left right button to choose turn on off Backlight mode 1...

Page 15: ...k Light Compensation To identify the over luminance area by backlight and proceed masking the area 3 1 SELECT Select the areas which needs to be adjusted 4 areas are selectable 3 2 DISPLAY Display the...

Page 16: ...urn to last page or Save End Menu 1 4 3 MANUAL WB Calibrate the white light balance to find out right White color 1 AWB Auto white balance 2 ATW Trace white area and auto calibrated 3 AWC SET Semi aut...

Page 17: ...ction NR To obtain high quality output image and increase file compression See below 1 2D NR LOW MIDDLE HIGH Edge Preserving 2D NR 2 3D NR LOW MIDDLE HIGH Motion Adaptive 3D NR 3 Return Return to last...

Page 18: ...right to turn on or off 1 1 FREEZE Turn ON OFF to freeze image If Freeze function is turn on the 1 2 Mirror function can not be used at the same time 1 2 MIRROR Image rotatory Horizontal or Vertical 1...

Page 19: ...nge as MIRROR function is ON 2 2 DISPLAY Display the selected area Position and area can be set in 2 1 2 3 SENSITIVITY The sensitivity to detect whenever object moves The lower value gets the higher s...

Page 20: ...Select to show MOTION DETECTED when detect moving image 2 6 3 TIME Set Frame pausing time when detect the image is not moving 2 6 4 RETURN Return to last page or Save End Menu 2 7 DEFAULT Return to fa...

Page 21: ...ill follow the threshold setting to adjust brightness and compensate the dead pixel 4 1 2 LEVEL Set the threshold value to judge if compensation is needed 4 1 3 RETURN Return to last page or Save End...

Page 22: ...it needs to be corrected 4 2 5 AGC Auto Gain Control When light source is not enough AGC will follow the threshold setting to adjust brightness and compensate the dead pixel 4 2 6 SENS UP Raise up th...

Page 23: ...value increases the higher contrast along near edges of the image 1 1 LEVEL Adjust Image Sharpness level 1 2 START AGC Set start levels to adjust sharpness 1 3 END AGC Set end levels to end adjust sh...

Page 24: ...l 2 4 RETURN Return to last page or Save End Menu 3 LSC Lens Shading Correction Use Lens shading correction to average the luminance of image 4 VIDEO OUT Select NTSC or PAL for TV output 5 RETURN Retu...

Page 25: ...n the IR receiver area 1 IR remote control aiming area f The indicator will blink whenever buttons are pressed If the indicator did not blink means the signal was not delivered and please repress agai...

Page 26: ...adaptor is only compatible with the cord in the box Please do not use other adaptor 2 USB j USB port for PC connection or Firmware update 3 HDMI K The HDMI port is used to connect the microscope to a...

Page 27: ...e stand and then screw the microscope onto the universal joint l on the gear box 1 5 4 GN08 Light Socket 1 Coaxial Light Socket m Connect Power cable from GN08 to Microscope LED can control from both...

Page 28: ...chart as reference for the working distance Recommend to find focus from the minimum magnification Zoom out to the end easier to find focus Use Gearbox to quick find the shape of object once the shape...

Page 29: ...croscope accessory 1 7 1 White balance card The white side is used to calibrate the white balance If the object is tiny place it onto the white balance card and move the card instead of the object UM2...

Page 30: ...lfunction if it encounters strong collision vibration or distortion 2 1 4 Turn the microscope off before cutting off the power supply do not forced cut off the power supply 2 1 5 Do not face the lens...

Page 31: ...age USB 3 0 Port Type C output YUV MJPE format Max res 1080P Focus control IR remote control Power Supplier Adaptor Output DC 5 0V 2 0A Input AC 100 240V 50 60Hz P o w e r Consumption A C 1A Max S i z...

Page 32: ...e the device or the device is dropped or damaged please switch off and remove the power supply to avoid fire and electric shock Do not look steadily into Light sources after switching on the host as i...

Page 33: ...r etc Services caused by any of the following situations in the period of the warranty shall not be provided free of charge 1 Improper use or disassembly repair or refitting 2 Any damages to the devic...

Page 34: ...or Confirmation Stamp is necessary for validation of the Warranty Distributor s seal shall include name of the shop telephone and address Please ask the distributor to fill in the name of the shop add...

Page 35: ......

Page 36: ...HTTP WWW VITINY COM MicroLinks Technology Corp All rights reserved...

Reviews: