VSC8228 Evaluation Board
Software / User Usage Guide
Applications Engineering
____________________________________________________________________________
________________________________________________
9 of 13
_______________________________________________
Rev 1.0
Confidential
01/25/05
6. G
ETTING
S
TARTED WITH THE
S
OFTWARE
a)
Verify that jumpers are installed on J14 in the TWSI SDA and TWSI SCK positions to use the RS-232 Port
b)
Verify that SW6 is set up as described below. This will configure the part to use the Two-wire Serial Interface as
described in the device datasheet.
O
N
7
1
2
3
4
5
6
DEFAULT LOW
SW6
PIO0
PIO1
PIO2
PIO3
PIO4
PIO5
PIO6
c) Apply 3.3V to power up the board. Start the program by clicking on “
Start
” and then navigating from the
programs menu to select “
VSCControlSoftware
.” The first time the program is run, it will display a list of several
Vitesse devices. Select the VSC8228. To switch from another Vitesse device to the VSC8228, select “
File”
and
then
“Open
” on the main menu to open the “
VSC8228.RegFile”
from the default directory.
•
C:\Program Files\Vitesse Semiconductor Corporation\VSCControlSoftware\VSC8228RegFile
After you open
VSC8228.RegFile
, the following VSC8228 register window will open as shown below.