ENVI Series: VTD-MV-VN / VTD-MV-VRN
8
5.
VTD-MV-VN / VTD-MV-VRN Installation
5.1.
Attaching Dome to Mounting Location (Flush / Surface Mount)
1.
Remove Dome Cover
Use the provided Torx wrench to unscrew the vandal proof screws and remove the dome
cover.
2.
Flush Mount Installation
Using four St4x30 screws, attach the flush mount base to a sturdy surface. Optional flush
mount decorator plate. Model: VT-MD
3.
Surface Mount Installation
Drill pilot holes at the mounting location using the provided mounting template. Using four
St4x30 screws, mount the surface mount housing to a sturdy surface. Using four ST4x12
(Indoor) screws or M4x10 (Vandal-proof) screws, attach the flush mount base to the surface
mount housing.
5.2.
Junction Box Installation
Mighty Domes can easily be flush or surface mounted to an electrical junction box (4S J-Box) using the pre-
drilled mounting holes on either the surface mount housing or the flush mount base.