2.10

 

Warranty 

 

The Warranty Chart is a separate document attached to every new product. 

 

2.11

 

Warranty instructions 

 

Failure to comply with the procedures presented below will result in the loss of warranty. 

 

 

In case of any damage, the use of the device should be discontinued until the moment of repair.

 

 

 

No unauthorised repairs are permitted.

 

 

 

No original parts of the device can be replaced with self-made or commercially available spare parts.

 

 

The only person authorised to maintain the assembly and all the repairs to the device is the person authorized by 
the manufacturer. 

 

mdh Sp. z o.o. hopes that the present manual will meet all your expectations and needs in the field of usage of Dynamic 

Parapodium  Model  PD150,  PD180,  PD200.  However,  if  you  think  that  any  modifications  or  supplements  to  the  above 
instructions are needed, please share your opinion with us, and we will consider introducing the appropriate changes. 

 

It  is  a  great  challenge  for  mdh  sp.  z  o.o.  to  create  a  perfect  dynamic  orthosis  that  could  serve  all  disabled  people  with 
paraplegia, irrespective of the severity of the disorder. It is our aim for the next few years to enable each disabled person to 
stand up and walk. Therefore, we would like to invite all the users of the Dynamic Parapodium Model PD150,Pd180, PD 200 
to co-operate with us, in order to improve the existing device and to develop new, more advanced orthoses. 

 

ATTENTION: 

The  models  of  Dynamic  Parapodium  delivered  to  you  may  slightly  differ  from  the  devices  on  the  pictures

 

because mdh sp. z o.o. constantly improves them. 

 
 
 

3. Symbols 

   

Confirmation  of  compliance  with  EU 

standards 

 Manufacturer 

 Date of production 

   Read the user's manual 

   Warning 

  Catalog number 

  Serial number 

   Protect from humidity 

   Protect from sunlight 

    Permitted user weight. 

 

   Use inside buildings 

 

  The possibility of fingers jamming. 

 

 Temperature of storage and use 

 
 
 
 
 

15 

Summary of Contents for PARAPODIUM PD 180

Page 1: ...Dynamic Parapodium Model PD150 PD 180 PD 200 User s Manual 09 2016...

Page 2: ...PRELIMINARY REHABILITATION PROGRAMME FOR THE PERIOD OF ADAPTATION OF THE ORGANISM TO THE DEVICE 5 2 USER S MANUAL 6 2 1 GENERAL PRINCIPLES OF SAFETY 6 2 2 GENERAL INFORMATION 7 2 3 PREPARATION OF THE...

Page 3: ...ralysis allowing to assume upright position without additional support on crutches and sitting up Dynamic Parapodium parapodium orthosis system making active rehabilitation and movement gait possible...

Page 4: ...4 Most Common Systemic Disturbances Likely To Occur In Paraplegia WARNING The prerequisite for starting rehabilitation of the patient making use of the Dynamic Parapodium is previous consultation wit...

Page 5: ...n and inappropriate distribution of blood which leads in high temperature of the environment to the earlier occurrence of the over warming effect than in healthy subjects associated with the risk of d...

Page 6: ...round During the brakes in the previous exercise inclining and turning the trunk in various directions and or active training of the upper extremities with various loads 3 Prolongation of the period o...

Page 7: ...situations or serious injury to the user 2 2 General information The purpose of this manual The manual contains detailed information concerning the conditions of usage of the Dynamic Parapodium Model...

Page 8: ...lanes The plane perpendicular to the axis of the runners extending through the corset hanger joint after positioning the patient in the parapodium this plane extends through the axis of their hip join...

Page 9: ...unners from the ground is sufficient to initiate the movement of the parapodium The runners are equipped with lateral safety supports It is very difficult to make parapodium swing beyond the support p...

Page 10: ...ient feels safe support for the leg but without hyperextension of knee joints This ensures not only safety but also correct position of the body in the parapodium which makes walking much easier The p...

Page 11: ...relation to the axis of corset hanger joints if the patient is bent forward act according to Assembly Instructions if the patient is bent backward act according to Assembly Instructions WARNING Durin...

Page 12: ...the parapodium is assembled incorrectly act according to Assembly Instruction When the patient moves the trunk and lifts the runners from the ground the front of the runners fall down Assembly Instruc...

Page 13: ...ld appliances is acceptable Leather upholstery should be cleaned and conserved with special agents used to clean leather clothing Velour upholstery should be washed at 40 C with water containing mild...

Page 14: ...e Dynamic damages such as fissures found replace Parapodium deformations or any other visible damaged elements with damages which can affect device new ones usage or safety of the user Measure height...

Page 15: ...ease share your opinion with us and we will consider introducing the appropriate changes It is a great challenge for mdh sp z o o to create a perfect dynamic orthosis that could serve all disabled peo...

Page 16: ...24 www viteacare com Dynamic Parapodium Model PD150 PD180 PD200 User s Manual is a property of mdh Sp z o o All rights reserved Attention The devices presented in this manual are protected by appropri...

Reviews: