32
VITA V60 i-Line
®
22 Recording process data / firing data system (FDS)
In order to view firing curves in the FDS, the corresponding process data must
be exported from the furnace. Create a folder called "processdata" on any
USB flash drive. With the device switched off, insert this USB flash drive into
the USB port of the device. Switch on and start up the device.
After startup, the process data from the last 19 firing cycles is stored in the
"processdata" folder.
The firing data is only saved to the USB flash drive when it is inserted
before the device has been switched on using the main switch!
The firing data is then managed on the PC using the firing data administration
program FDS (firing data system) for PC use (accessories). This enables
traceability by ensuring that completed firing programs are allocated to the
device.
Using the FDS, the most recently completed firing cycles can be investigated
in the event of problems.
22.1 Exporting / importing programs
In order to export all 200 programs (individual export is not possible), create
a folder named "programs" on any USB flash drive and connect this to
the furnace while the furnace is switched off. Once the furnace has been
switched on and started up, all programs are copied to the USB flash drive.
To import the programs to a furnace, connect the USB flash drive with the
"programs" folder (including the programs) to the furnace while the furnace is
switched off.
Once the furnace has been switched on and started up, all programs are
copied to the furnace.
In brief:
Empty "programs" folder = programs are copied from the furnace to the flash
drive
Full "programs" folder = programs are copied from the flash drive to the
furnace
Please note that all previous programs are deleted when the new programs
are copied to the furnace.