A.9
GPI
Trigger Type
Trigger Value
Flank
Description
Channel
Port number
Change
Port state changes
Channel
Port number
Down
Port is closed
Channel
Port number
Up
Port is opened
Binary
Combination value
-
A combination of ports being closed
Use the Binary trigger type to catch port combinations when they are set as
digital. Specify the port combination by adding the values that correspond to
the ports (see table below). This value is entered as the trigger value.
Port
Value
1
1
2
2
3
4
4
8
For example, to trigger on both port 1 and 2 being closed fill in trigger value 3
(1+2). To trigger on port 5 and 6, fill in value 48 (16+32).
50