11
Omnio P/L
6/2020 (EN)
5.5 Components and tools (illustration)
1x
1x
1x
3x
SW 5
Fig. 29: Components and tools
Connection frame designation
Electrified upright designation
Non-electrified upright designation
5.6 Installing the structure
5.6.1 Fixing the first upright
Installation of electrified structures starts with the electri-
fied upright. Installation of non-electrified structures can
start with any upright. The installation of an electrified
upright is shown here by way of example.
1. Swivel the mount to insert it into the upright.
90°
1.
Fig. 30: Inserting the mount into the upright
2. Make sure that all four screws on the connection
frame are loosened.
It is easier to press the frame down if the screw head
is pressed in during installation.
3. Guide the electrified corner of the frame over the
mount and press it downwards.
Â
The mount must be flush with the bottom of the
frame. This can be done by feel or by performing
a visual inspection
4. Screw in all screws with a hexagon wrench or a cord-
less screwdriver with a hexagon bit (SW5).
5. Tighten all screws with a torque of 10 Nm.
2.
2.
3.
4.
Fig. 31: Fixing the first upright