Installation Notes:  

The top cover should only be accessed by authorized service personnel or manufacturer. Do not obscure the detector field of view with large objects. Install 
in position such that expected intruder motion is perpendicular to the zones of detection.  
Alarms triggered by conditions such as weather, blowing leaves and brush, or related environmental conditions, etc., need to be considered when assessing 
the installation and application. It is recommended that the intrusion detection unit is not to be connected to an alarm initiating circuit but may be connected 
to a trouble alarm circuit if nuisance trips are not tolerable. 

COVER CLOSURE 

 

 

1.

 Release locking 

2.

 Adjust 

3.

 Lock 

4.

 Release locking 

5.

 Adjust 

6.

 Lock 

7.

 Turn cover and push slider 

8 & 9.

 Put back cover 

10.

 Secure with screw 

 

A. 

Vertical angle steps 

Figure 3 - Adjustment and Cover Closure 

2.2 Battery Insertion 

It  is  recommended  to  perform  the  first  batteries  insertion  on  a  flat  surface  (see  Figure  4).  After  battery  insertion,  the  LED  will  flash  for  60 
seconds and then the detector will enter a 15 minutes' local diagnostic mode. 

Summary of Contents for TOWER CAM PG2 TOWER CAM PG2

Page 1: ...rature compensation Immunity to pets weighing up to 18 Kg 40lb see Table 1 Built in swivel bracket The camera s features are as follows Up to 10 cameras can be enrolled Images multiplexed from all enr...

Page 2: ...re the installation options recommended for reducing the probability of false alarms from pets Event counter One region Correct Installation Incorrect Installation A Mark drilling point B Screw hole f...

Page 3: ...installation and application It is recommended that the intrusion detection unit is not to be connected to an alarm initiating circuit but may be connected to a trouble alarm circuit if nuisance trips...

Page 4: ...Dispose of used battery according to the manufacturer s instructions Caution The battery used in this device may present a risk of fire or chemical burn if mistreated Do not disassemble heat above 66...

Page 5: ...her or not to activate the alarm LED indication Optional settings ON default and OFF PIR SENSITIVITY Define if the detector operates at regular or high PIR sensitivity or that at least one detection z...

Page 6: ...ignal strength is not acceptable If you receive a poor signal from the detector re locate it and re test until a Good or Strong signal strength is received Note For detailed Diagnostics Test instructi...

Page 7: ...o an outlet on a circuit different from the one that supplies power to the receiver Consult the dealer or an experienced radio TV technician WARNING Changes or modifications to this unit not expressly...

Page 8: ...RECTLY ARISING FROM PURCHASER S USE OR INABILITY TO USE THE PRODUCT OR FOR LOSS OR DESTRUCTION OF OTHER PROPERTY OR FROM ANY OTHER CAUSE EVEN IF MANUFACTURER HAS BEEN ADVISED OF THE POSSIBILITY OF SUC...

Reviews: