D-301438 AMBER SELECT / AMBER SELECT
X
USER’S GUIDE
3
CHECK
BUTTON
EMERGENCY
BUTTON
SPEAKER
CALL
BUTTON
MICROPHONE
TROUBLE
LED
STATUS
LED
POWER
LED
DIRECT LINK
BUTTONS
DISPLAY
Figure 1
– Front View
PUBLIC
TELEPHONE
EXCHANGE
TEL. LINE
UP TO 29
WIRELESS DEVICES
(DETECTORS
/ TRANSMITTERS)
MCT-241 MD
NEXT K9-85
MOTION
DETECTOR
MCT-302
DOOR
CONTACT
GAS DETECTORS
MCT-220
EMERGENCY
BUTTON
MONITORING
CENTER
PRIVATE
PHONE
FLOOD
DETECTOR
MCT-550
MCT-211
SMOKE DETECTOR
MCT-425
PENDANT TRANSMITTER
MCT-212
MCT-442
MCT-440/441
MCX-600PERS
REPEATER
Figure 2
– System Configuration
SPECIFICATIONS
General Data
Transmitter Battery Life:
3 years (for typical use)
Frequency (MHz):
315, 433.92, 868.95, 869.2125.
Display:
Dual line, backlit 16-character display
(AMBER SELECT only) with 3
LED indicators.
UL Compliant (AMBER SELECT
X
only):
Battery Pack:
NI-MH 9.6 V, 1.8 Ah, type GP 0-9912-G.
Supply Voltage:
12 VAC, 1 A (via 120VAC/60Hz
transformer).
Non-UL Compliant (AMBER SELECT
X
only):
Battery Pack:
NI-MH 7.2 V, 1.3 Ah, type 103-301179.
Supply Voltage:
9 VAC, 750 mA.
Compliance:
Complies with FCC part 68 and part 15,
and UL 1637 Home Health Care Signaling Equipment.
MCT-425 is designed to comply with UL 268 and UL
985.
The
system
shall
be
installed
in
accordance
with
Chapter
2
of
the
National
Fire
Alarm
Code,
ANSI/NFPA
72
(National
Fire Protection Association, Batterymarch Park, Quincy,
MA 02269).
LEDs:
POWER (Green):
Normally ON, indicating that your
system is properly connected to the power outlet.
TROUBLE (Red):
Normally OFF. If LED flashes,
there is a problem with the AMBER SELECT /
AMBER SELECT
X
or one of the devices (described
on the display of AMBER SELECT).
STATUS (Yellow):
Normally OFF, which indicates
the system is in AWAY mode. ON when unit is in
HOME mode.