background image

PAGE 7

10

11

12

13

14

15

16

17

18

1

2

3

4

5

6

7

8

9

19

19

Standard flue components

#

Code

Description

1

VF-3-60-001

AIR FLUE RAIN CAP

2

VF-3-60-203

AIR FLUE SAFETY VENT 1000MM

3

VF-3-60-202

AIR FLUE SAFETY VENT 500MM

4

VF-3-60-201

AIR FLUE SAFETY VENT 250MM

5

VF-3-60-245

AIR FLUE SAFETY VENT 45 ELBOW

6

VF-3-60-246

AIR FLUE ELBOW SUPPORT BRACKET
KIT

7

VF-3-60-003

AIR FLUE SUPPORT 2

8

VF-3-60-002

AIR FLUE SUPPORT 1

9

VF-3-60-108

AIR FLUE STOVE PIPE TO SAFETY VENT
TRANSITION

10

VF-3-60-110

AIR FLUE CEILING RING - 80MM

11

VF-3-60-105

AIR FLUE STOVE PIPE 620-1080MM
ADJUSTABLE

12

VF-3-60-104

AIR FLUE STOVE PIPE 420-610MM
ADJUSTABLE

13

VF-3-60-145

AIR FLUE STOVE PIPE 45 ELBOW

14

VF-3-60-107

AIR FLUE STOVE PIPE 1200MM

15

VF-3-60-106

AIR FLUE STOVE PIPE 1000MM

16

VF-3-60-102

AIR FLUE STOVE PIPE 500MM

17

VF-3-60-100

AIR FLUE STOVE PIPE 250MM

18

VF-5-01-001

100MM ADJUSTABLE ELBOW 0-90
DEGREES

19

VF-3-60-090

AIR FLUE STOVE PIPE T SECTION

20 VF-3-60-091

AIR FLUE ADJUSTABLE SNORKEL

Summary of Contents for Safety Vent AIR

Page 1: ...Safety Vent AIR Instruc on Manual...

Page 2: ...mic insula on with a density of 128 kg m air gap of 20 mm 20 mm Morgan Frax ceramic insula on 128 kg m and outer wall of 0 5 mm SS 304 stainless steel VisionLINE Stove Pipe AIR is a double layer pipe...

Page 3: ...od Prepara on Before installa on planning is essen al for an efficient safe and cost effec ve installa on ONLY VisionLINE safety vent AIR and VL Stove Pipe parts can be used for installa on Improvised...

Page 4: ...ucting any additional frame work If the roof cavity is used as usable living or storage space or has blown in insulation an a ic shield is recommended to ensure the 50mm clearance to the Safety Vent A...

Page 5: ...t if you require smaller sections please contact your distributor Safety Vent pipe does not require securing screws or rivets once twist locked together however if connec ng mul ple sec ons together t...

Page 6: ...ntake system a T piece sec on can be used Part number VF 3 60 090 as the final VL stove pipe sec on which can then be connected to the rear air inlet either by flex pipe not supplied or the VisionLINE...

Page 7: ...eight requirements per AS NZS 2918 Elbow support bracket kit VF 3 60 246 Use of bends 45o Bends can be used on this flue system Either the stove pipe flue or the VisionLINE safety vent flue can be off...

Page 8: ...60 002 AIR FLUE SUPPORT 1 9 VF 3 60 108 AIR FLUE STOVE PIPE TO SAFETY VENT TRANSITION 10 VF 3 60 110 AIR FLUE CEILING RING 80MM 11 VF 3 60 105 AIR FLUE STOVE PIPE 620 1080MM ADJUSTABLE 12 VF 3 60 104...

Page 9: ...3 mm 148 5 Ceiling Ring VF 3 60 110 Flush spigot adapter 193 L 30 Adjustable Stove pipe 193 L 30 Stove pipe Part number Joined length Total length VF 3 60 100 220mm 250mm VF 3 60 102 470mm 500mm VF 3...