15
9.5 Installation
•
Guide the flexible hose
6
through the existing flue
7
.
•
Attach the slider
5
to the bottom of the flexible hose
and secure this in place using two Parker screws.
•
Keep the bottom of the slider at the same height as
the bottom of the flue or ceiling. Shorten the flexible hose
to approximately 100mm above the chimney coping.
•
Attach the mounting plate to the flexible hose on the roof
8
, clamp it with a hose bracket. Stainless steel Ø90 to 165,
secure the whole with Parker screws.
•
Attach the mounting plate to the chimney coping watertight
on the roof
8
using silicone sealant and stainless steel
screws.
•
Install the roof pass-through
9
and secure it in place using
the supplied clamping strip (10).
•
The slider
5
will protrude approximately 100mm
underneath the flue or ceiling after installation.
•
Attach the inner mounting plate
4
gastight against
the bottom of the structural flue or against the bottom of
the concrete floor using silicone sealant and screws.
•
Position the unit in accordance with the instructions of
the unit manufacturer
•
Install a minimum of 1 metre of concentric flue type
THC CC
2
.
•
Extend the concentric flue using sections
2
up to
a minimum of 100mm in the structural duct. Finally, turn
the clamping strip by hand in the mounting plate inside
3
.