11
7 GAS-TECHNICAL SPECIFICATIONS
Type of indication(s)
TRIMLINE 70 SL (1023)
Unit type
C11, C31, C91
Concentric extraction system
Holetherm CC 100-150
Gas type
G25.3
G20/G25
G20
G20/25
Supply pressure in mBar
25
20
20
20/25
Country/Countries
NL
DE
AT/CH/CY/CZ/DK/EE/ES/FI/
FR/GB/GR/HR/IE/IT/LT/LU/
LV/NO/PT/RO/SE/SI/SK/TR
BE/FR
Category
I
2
EK
I
2
(43,46-45,3 MJ/m
3
)
I
2
ELL
I
2
H
I
2
E
+
Primary air
2x5mm
2x5mm
2x5mm
2x5mm
Supply pressure
mBar
25
20
20
20/25
Burner pressure - high position mBar
22
14,6
14,6
14,6/18,2
Burner pressure - low position mBar
11,2
8,2
8,3
8,3/10,3
Injector orifice
Ø mm
1.8
1.8
1.8
1.8
Pilot light injector
CODE
272
272
272
272
Small position orifice
mm
1.8
1.8
1.8
1.8
Load Hs
kW
5.3
5/4.2
5
5
Hi load
kW
4.74
4.5/3.77
4.5
4.5
Gas consumption
m³/h
0.57
0.48/0.46
0.48
0.48
Nominal power - high position kW
3.97
3.8/3
3.8
3.8
Nominal power - low position kW
2.7
2.8/2.2
2.8
2.8
NOx Hs
mg/kWh
75.5
83/75
83
83
Efficiency class NE613
1
1
1
1
Useful return (NCV) system**
For nominal heat output
%
83.7
83.7/81.4
83.7
83.7
For minimal heat output
%
81.3
80.5/79.5
80.5
80.5
Supplementary electricity consumption
Nominal
kWh
0
0
0
0
Stand-by
kWh
0
0
0
0
Energy efficiency***
Energy efficiency index
EEI
78
78/75
78
78
Energy label
C
C/D
C
C
NOx Hi
class
5
5
5
5
Heat output type/room temperature control
Indirect heat functionality
No
Single stage heat output, no room temperature control
No
2 or more manually-adjustable stages, no control of the room temperature
No
With mechanical control of room temperature by thermostat
No
With electronic control of room temperature
Yes
With electronic control of room temperature plus day-time switch
Yes
With electronic control of room temperature plus week-time switch
Yes
Other control options
Control of room temperature with presence detection*
Yes
Control of room temperature with open window detection*
Yes
With remote control option
Yes
*in combination with home automation
**shortest system path
*** EU directive 2015-1186/1188