Technical data
Technisches Handbuch
Version 5.2
17
OUTP2<x,xxx>
see OUTP1<x,xxx>
OUTP3<x,xxx>
see OUTP1<x,xxx>
OUTP4<x,xxx>
see OUTP1<x,xxx>
OUT0 Simultaneous switching of the outputs OUT1…4
Write:
OUT0<OUT1,OUT2,OUT3,OUT4>
Answer: none
_OUT0< OUT1,OUT2,OUT3,OUT4>
Answer: „ACK“
OUT0<0.X.1,0.X.1,0.X.1,0.X.1> 0 = Switches OUTx off
with CFO1<0,xxxx> Output OUT1.24 is switched off and
the PWM signal at output OUT1.PWM is stopped.
with CFO1<1,xxxx> the PWM signal is stopped at Output
OUT1.24.
1 = Switches OUTx on
with CFO1<0,xxxx> Output OUT1.24 is switched on and
the PWM signal at Output OUT1.PWM is output.
with CFO1<1,xxxx> the PWM signal is output at Output
OUT1.24.
X = no change at OUTx
OUTP0 Simultaneous switching of outputs OUT1...4 with PWM value
Write:
OUTP0<OUT1,PWM1,OUT2,PWM2,OUT3,PWM3,OUT4,PWM4>
Answer: none
_OUTP0<OUT1,PWM1,OUT2,PWM2,OUT3,PWM3,OUT4,PWM4>
Answer: „ACK“
OUTP0<
0.X.1
,0..100,..
..,
0.X.1
,0..100>
0 = Switches OUTx off
with CFO1<0,xxxx> Output OUT1.24 is switched off and the PWM
signal at output OUT1.PWM is stopped.
with CFO1<1,xxxx> the PWM signal is stopped at Output OUT1.24.
1 = Switches OUTx on
with CFO1<0,xxxx> Output OUT1.24 is switched on and the PWM
signal at Output OUT1.PWM is output.
with CFO1<1,xxxx> the PWM signal is output at Output OUT1.24.
X = no change at OUTx
OUTP0<0.X.1,
0..100
,..
..,0.X.1,
0..100
>
0..100% Brightness for OUTx.