![Vision tools 09V0002B Technical Manual Download Page 17](http://html.mh-extra.com/html/vision-tools/09v0002b/09v0002b_technical-manual_1032169017.webp)
Technical data
Technisches Handbuch
Version 5.2
15
Read:
RCFI1
Answer: CFI1<0..4,0..4,0..1,0..999>
RCFI2
Answer: CFI2<0..4,0..4,0..1,0..999>
RCFI3
Answer: CFI3<0..4,0..4,0..1,0..999>
RCFI4
Answer: CFI4<0..4,0..4,0..1,0..999>
RCFI5
Answer: CFI5<0..4,0..4,0..1,0..999>
RCFI6
Answer: CFI6<0..4,0..4,0..1,0..999>
RINP Reads the inputs IN1...6
RINP1
Answer: INP1<0..1>
RINP2
Answer: INP2<0..1>
RINP3
Answer: INP3<0..1>
RINP4
Answer: INP4<0..1>
RINP5
Answer: INP5<0..1>
RINP6
Answer: INP6<0..1>
CFO/RCFO Sets the outputs OUT1...4
Write:
CFO1<MODE,Delay>
Answer: none
_CFO1<MODE,Delay >
Answer; „ACK“
CFO1<
0..1
,0..9999> 0 = OUT1.24 = Switch, OUT1.PW = PWM (pulse width modulation)
1 = OUT1.24 = PWM, OUT1.PW = off
CFO1<0..1,
0..9999
> 0..9999 ms Switch-on delay OUT1.
CFO2<x,xxxx>
see CFO1<x,xxxx>
CFO3<x,xxxx>
see CFO1<x,xxxx>
CFO4<x,xxxx>
see CFO1<x,xxxx>
Read:
RCFO1
Answer: CFO1<0..1,0..9999>
RCFO2
Answer: CFO2<0..1,0..9999>
RCFO3
Answer: CFO3<0..1,0..9999>
RCFO4
Answer: CFO4<0..1,0..9999>