Instruction Manual – Verdanium Geo – Ver. 1.1.1 – 12.2021
Instruction Manual – Verdanium Geo – Ver. 1.1.1 – 12.2021
46
47
Filter change
This completes the annual filter change and you can reconnect the Verdanium Geo and put it into operation.
To do this, use the IB program in the operating mode menu.
Post-filter replacement
You must change the post-filter every 12 months. Refer to the illustrations below and proceed as follows:
Before inserting the new filter units, remove the
protective cap from the filters. You can easily
push it upwards to remove it.
Thanks to the tilting filter heads, you can change
the filter without additional tools. Take the GAC
post-filter unit out of the Verdanium Geo in a for-
ward direction.
Turn filter cartridge counterclockwise 90° out of
the filter head to change the filter unit.
Insert the new filter cartridge into the filter head
by rotating the filter cartridge 90 ° clockwise.
Start-up after filter change
You must put the system into operation after each filter change or after a new installation. For this purpose,
select the commissioning program (IB-Programm) in the operating mode menu (Betriebsart).
Navigate with the ( + )- or ( - ) key to activate the operating mode, press the
OK-button
.
This operating mode (IB-Programm) assumes that the Verdanium Home is properly connected. The water
inlet and withdrawal tap must be open.
In the first pass, the program rinses the pre-filters (Filter spülen).
When rinsing the membranes (Membran spülen), the disinfectant is removed from the membrane and
drains into the waste- water connection.
During the last phase of recommissioning, the Verdanium Home rinses the ultra-pure water side of the
membranes and the post-filters (Permeat spülen).
When the IB-Programm is completed, and the extraction tap is open, the Verdanium Home changes automa-
tically to permeate production. The Verdanium Home is now ready for use.
1.
2.
1.
2.
Automatic
Automatic
Button
BETRIEBSART
mit “+“ / “-“ Taste
auswählen
IB-PROGRAMM
ESC ←
→ OK
Filter spülen
ESC ←
030%
PERMEATPRODUKTION
Gerät in
Betrieb
ESC ←
Permeat spülen
ESC ←
060%
Membran spülen
ESC ←
090%