- 4 -
2 SPECIFICATIONS
Note: Performance may be degraded at high levels of repetitive electrostatic
discharge; however, no damage to the unit will occur.
2.1 Input
Connections
Type:
Tool-free eccentric lever release
Quantity:
Four
Wire size:
16 to 28 AWG [1.29 to 0.31mm
Φ
]
2.2 Bridge
Configurations
Types:
Quarter-, half-, and full bridges
Bridge Impedance:
60 to 2000
Ω
Internal Bridge Completion:
Quarter bridge:
120
Ω
, 350
Ω
and 1000
Ω
±0.01%
Half bridge:
1000
Ω
±0.01%
2.3 Display
Type:
128 x 64 pixel FSTN positive, gray transflective
LCD with backlight
Update rate:
2 updates/second typ.
2.4 Data
Conversion
A/D Converter:
Delta-sigma with integral chopper-
stabilized programmable gain instrumentation amplifier
Resolution:
24 bits. Noise-free resolution: 18 bits typ.
Output rate:
Normal mode:
50 or 60 samples/sec.
Analog output mode:
480 samples/sec.
Filter: Integrated linear phase FIR Sinc
5
filter followed
by a Sinc
3
filter with a programmable decimation rate.
Software selectable output rate provides >120 dB rejec-
tion of 50 or 60Hz and higher level harmonics.