TITEL HOOFDSTUK
EN
VirtuFit iConsole HTR 2.1 Hometrainer
16
TROUBLE SHOOTING
Display shows no values
If the display does not show any values, you can try to check the sensor cables and the cables in the back
of the display. If this still does not work, you can move the sensor slightly.
The device beeps
If necessary, lubricate parts with silicone spray. Check that all nuts and bolts are tightened. It may be that a
screw is too loose or too tight, this creates friction and makes the device appear to beep. If this is the case,
try to find out exactly where the beep comes from and then tighten or loosen this screw. It must always be
possible to loosen the screws with your hands. If this is not possible, the screw is too tight.
No resistance
First check whether you can hear the motor running. You will hear the motor running briefly when you
increase or decrease the resistance. If you hear the engine running, all electronics are in order, but the
V-belt is probably over. You can then open the housing and put the V-belt back on it. If you do not hear
the motor running, it is possible that the motor or the display is defective. First check whether the cable
running upwards in the pipe is still properly connected.
Ticking sound
It is possible that the flywheel (in the housing) comes against a cable with each pedaling movement. This
may be disturbing but will not permanently damage your crosstrainer. To fix this, open the housing and
move the cable or fix it with for example a tie wrap.
Heart rate display is not functioning
There can be various reasons for this:
• The sensor cables that run from the heart rate sensor to the display are not properly installed or have
become detached during use.
• The sensors may become damp, dirty or greasy. So you have to clean them regularly.
The console is not working
If there is no signal when pedaling, check if the cable is properly attached.