Working in Mono, but...
Problem
Video is functioning properly in both eyes but cannot fuse image.
Check
Check that IPD is properly adjusted.
Comment
Contact Virtual Research if problem persists
Working in Stereo, but...
Problem
Stereo LED does not light.
Check
Video not connected at right input or at computer.
Comment
If symptom occurs while using sync on green and connections are correct, contact
Virtual Research for firmware update.
Problem
HMD functions properly in mono but not stable in stereo.
Check
Video format sync for right channel identical to left (640x480 60 Hz). Both channels
must have the same sync configuration.
Comment
Video source for right channel must be identical format to left input.
Mechanical and Optical Problems
Problem
Circular black spot appears on LCD.
Check
Clean lenses with No-Fog cloth to clean any dust that may have formed.
Comment
This dot may be a result of leaving the V6 in direct sunlight, which will burn the
polarizer of the LCD. Do not try to fix this problem. Contact Virtual Research for
further assistance.
Problem
HMD seems front heavy.
Check
HMD cable and tracker cable should fall behind the users shoulder and down the users
back, not in front of the user.
Problem
Headband ratchet knobs too loose or too tight.
Check
Adjust ratchet tightness with Phillips #2 screwdriver at center of ratchet knob.