![Virax 570001 User Manual Download Page 48](http://html1.mh-extra.com/html/virax/570001/570001_user-manual_1029963048.webp)
Page 48
Enter the temperature and press the Enter button. The following appears if the temperature was not entered
correctly:
Pressing the arrow key causes the machine to start up; pressing EXIT causes the program to spring into the main
menu without saving.
Place the electrical cutting unit between the two work pieces to be welded.
P250
–
P355 B PRO CNC:
Switch on the miller motor and lock the switch in place.
P500 - P630 B PRO CNC:
Verify the direction of rotation! The machines were polarized to turn clockwise
before leaving our factory!
Turn on the cutting unit, press buttons
(10)
and
(5)
on the hydraulic unit. The cutting disks must run in the
cutting direction. If they don‘t, use an appropriate tool to switch the phase
inverter on the electrical plug.
Risk of serious injury! During operation trimmer unit, stay a safe distance away from the machine,
and do not reach into the rotating knife. Use trimmer in working position only and return it into
the designated carrying frame immediately after use. Ensure that the safety switch functions
properly at all times to avoid any accidental starting of the trimmer away from the basic machine.
Close the clamping elements (press buttons
10
+
11
). Set the cutting pressure with the adjusting knob
(4)
.
Standard cutting pressure is up to 20 bar, but it can be raised to 40 bar, see point
3.5
.
An excessively high milling pressure can lead to overheating and damage to the miller drive. When
the milling drive is overloaded or at rest, raise the machine and reduce the pressure (s. 3.5).