![Virax 570001 User Manual Download Page 38](http://html1.mh-extra.com/html/virax/570001/570001_user-manual_1029963038.webp)
Page 38
Upon first use, check the date and time. To do this, press the GO button. (To change, see point
3.6
). To close the
menu, press EXIT
If you press GO key and no basic machine is connected, the following message appears:
“
Attention! No basic
machi
ne is detected. Please connect.”
If the error message still appears after connection, then the connection is defect, but there is the possibility to
weld and log in premium mode (see
3.2.4).
During first use, set the language. German is set by default. To change the settings, press and change using
OK in Setting 2
Use the arrow keys to select the desired language and press OK to confirm. The selected language will be saved
after the first welding process.
It is possible to switch the screen to standby mode. The screen saver becomes active when the hydraulic unit is
shut off with the button
(6)
.
Turn the hydraulic unit on (press button
(6)
).
After it is switched on, the heating element warms up.
The current temperature is shown on the display
(9)
. The control is active when a dot lights up on the display.
When the set temperature is reached, the two LEDs (current and target) light up. After another 10 minutes, the
heating element is ready to use. Check the temperature with a temperature measurement device.
To adjust the temperature of the heating element, see point
3.5
.
Risk of serious injury! The heating plate can reach temperatures of over 300°C ! We highly
recommend storing the heating plate in the designated carrying frame immediately after use!